The preoperative intraocular pressure level predicts the amount of underestimated intraocular pressure after LASIK for myopia.
نویسندگان
چکیده
AIMS To evaluate the statistical significance of the parameters that affect underestimation of intraocular pressure (IOP) after laser in situ keratomileusis (LASIK) for myopia. METHODS In this prospective case series study, patient age, axial length, preoperative corneal curvature, preoperative central corneal thickness (CCT), preoperative IOP, and ablation depth were studied to determine whether they affect the underestimation of IOP in the right eyes of 100 consecutive patients who underwent LASIK. RESULTS The preoperative IOP was the most important parameter for an amount of underestimated Goldmann applanation tonometric IOP (GAT) and non-contact tonometric IOP (ncIOP) at 1 month (r = 0.654, p<0.0001, R(2) = 0.427, and r = 0.694, p<0.0001, R(2) = 0.481, respectively) and 3 months (r = 0.637, p<0.0001, R(2) = 0.406, and r = 0.726, p<0.0001, R(2) = 0.527, respectively). Patient age was statistically significant for underestimating the GAT at 1 month, and both the ablation depth and CCT were statistically significant parameters for underestimating the ncIOP at 1 month and at 3 months by stepwise multiple regression analysis (F>4.000). However, these parameters had small bivariate correlation coefficients, and were considered as minor parameters. CONCLUSION Preoperative IOP is the most important parameter that affects an underestimation of IOP after LASIK for myopia. Eyes with a higher true IOP have a larger underestimation of the IOP after LASIK for myopia. From these results, the importance of the modulus of elasticity on IOP measurements was discussed.
منابع مشابه
The applicability of correction factor for corneal thickness on non-contact tonometer measured intraocular pressure in LASIK treated eyes.
PURPOSE To determine the applicability of central corneal thickness (CCT) based correction factor for non-contact tonometer (NCT) measured intraocular pressure (IOP) readings. METHOD A prospective, non-randomized study involved 346 eyes of 173 consecutive patients with age ⩾21 years undergoing laser-assisted in situ keratomileusis (LASIK) for myopia and/or myopic astigmatism. The CCT and IOP ...
متن کاملIncidence of interface fluid syndrome after laser in situ keratomileusis in Egyptian patients
PURPOSE To determine the incidence of interface fluid syndrome (IFS) secondary to steroid-induced elevation of intraocular pressure (IOP) following laser in situ keratomileusis (LASIK) in myopic Egyptian patients. METHODS This retrospective case series study was conducted at El-Gowhara Private Eye Center. The medical records of 1,807 patients (3,489 eyes), who underwent LASIK to correct myopi...
متن کاملFactors Influencing Intraocular Pressure Changes after Laser In Situ Keratomileusis with Flaps Created by Femtosecond Laser or Mechanical Microkeratome
The aim of this study is to describe factors that influence the measured intraocular pressure (IOP) change and to develop a predictive model after myopic laser in situ keratomileusis (LASIK) with a femtosecond (FS) laser or a microkeratome (MK). We retrospectively reviewed preoperative, intraoperative, and 12-month postoperative medical records in 2485 eyes of 1309 patients who underwent LASIK ...
متن کاملMyopic regression after phakic intraocular lens implantation and LASIK.
PURPOSE In myopia, biometry including the axial length is important, along with the refractive data. We compared the rates of myopic regression 3 years after phakic intraocular lens (pIOL) implantation and laser in situ keratomileusis (LASIK) after matching the preoperative axial length in highly myopic eyes of Japanese patients. METHODS This retrospective nonrandomized study included 133 eye...
متن کاملRefinement of Intraocular Pressure Measurements made by Ocular Response Analyzer following Laser in Situ Keratomileusis using M2 90 Moria Microkeratome for Egyptian Myopic and Astigmatic Patients
INTRODUCTION The Goldmann applanation tonometer readings were noted to be markedly reduced after Lasik surgery using a thin flap technique which is widely used nowadays, to correct a wide range of myopia and astigmatism. The Ocular Response Analyzer (ORA) is considered one of the important tools for refinement of Intraocular Pressure (IOP) measurements. The aim of this study is to evaluate and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 89 2 شماره
صفحات -
تاریخ انتشار 2005