Fully traceable absolute protein quantification of somatropin that allows independent comparison of somatropin standards.
نویسندگان
چکیده
BACKGROUND Measurement traceability in clinical chemistry is required to standardize clinical results irrespective of the measurement procedure and laboratory. The traceability of many protein substances is maintained by reference to the first standard produced, which may no longer exist, with values assigned by consensus. Independent methods that provide traceability to the Système d'Unité International for all relevant properties of a protein standard could remove reliance on the original standard preparations. METHODS We developed a method based on the traceable quantification of tryptic peptides released from the protein by isotope dilution mass spectrometry to compare 2 standard preparations of somatropin (recombinant human growth hormone), WHO 98/574 and Ph.Eur.CRS S0947000. Relative quantification using isotope-coded affinity tagging, isobaric tagging for relative and absolute quantification, and standard additions were also performed to validate the digestion method used and to determine whether any modifications were present. RESULTS The total somatropin content in both materials was determined and an uncertainty estimation undertaken [WHO 2.19 +/- 0.21) mg/vial, European Pharmacopeia 2.06 +/- 0.21 mg/vial]. Each uncertainty in this paper is a fully estimated uncertainty, with 95% CI (k = 2). Isotope coded affinity tag and standard addition results fully validated the robustness of the digestion method used. In addition, iTRAQ (isobaric tagging for relative and absolute quantification analysis) identified 2 modifications, neither of which impacted the quantification. CONCLUSIONS An independent method that does not rely on a preexisting protein standard has been developed and validated for the traceable value-assignment of total somatropin. The methods reported here address the amount of substance (mass fraction) of the standard materials but address neither biological activity nor other characteristics that may be important in assessing suitability for use as a calibrator.
منابع مشابه
Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملCalibration of Traceable Solid Mock 131I Phantoms Used in an International SPECT Image Quantification Comparison
The International Atomic Energy Agency (IAEA) has organized an international comparison to assess Single Photon Emission Computed Tomography (SPECT) image quantification capabilities in 12 countries. Iodine-131 was chosen as the radionuclide for the comparison because of its wide use around the world, but for logistical reasons solid (133)Ba sources were used as a long-lived surrogate for (131)...
متن کاملPharmacokinetics of human growth hormone administered subcutaneously with two different injection systems.
The bioavailability of recombinant human growth hormone (somatropin, CAS 12629-01-5) was compared between a transcutaneous jet injection device and subcutaneous cannula injection. Thirteen healthy male subjects received 8.64 IU somatropin once with jet and once with cannula injection in a randomized cross-over study. Baseline-corrected somatropin serum concentrations were evaluated with non-com...
متن کاملHuman pituitary growth hormone: restoration of full biological activity by noncovalent interaction of two fragments of the hormone.
The NH2-terminal 134 amino-acid fragment of the reduced-carbamidomethylated human somatropin molecule is found to react noncovalently with the COOH-terminal 51 amino-acid fragment in solutions of pH 8.4 at 2 degrees to restore full biological activity as evidenced by the rat tibia and pigeon crop-sac assays. In addition, circular dichroism spectra of the recombinant show the conformation to be ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 55 11 شماره
صفحات -
تاریخ انتشار 2009