Pulmonary function electronic monitoring devices: a randomized agreement study.

نویسندگان

  • Joao A Fonseca
  • Altamiro Costa-Pereira
  • Luis Delgado
  • Luis N Silva
  • Manuel Magalhães
  • M Graca Castel-Branco
  • Marianela Vaz
چکیده

STUDY OBJECTIVES To compare in a clinical setting the within-session reproducibility of two pulmonary function electronic monitoring devices (PiKo-1; Ferraris Respiratory Europe; Hereford, UK; and Spirotel; MIR; Rome, Italy) with one mechanical device (Mini-Wright Peak-Flow Meter; Clement-Clarke International; Harlow, Essex, UK), and to evaluate the accuracy of these devices using as reference an office pneumotachograph. DESIGN, SETTING, AND PARTICIPANTS After detailed instructions, adults without airways diseases and patients with stable asthma attending an outpatient clinic performed four sets of expiratory maneuvers, one set for each device, in a strictly random order. Each set comprised three maneuvers with 2 to 3 min of rest between them. MEASUREMENTS Reproducibility of FEV1 and peak expiratory flow (PEF) was assessed by a coefficient of variation (CV) and intraclass correlation coefficient (ICC), and accuracy was assessed by ICC and limits of agreement. RESULTS Of the 38 participants evaluated, 71% were women and 61% had asthma. Ages ranged from 18 to 58 years, and FEV1 ranged from 1.2 to 4.8 L. In all monitoring devices, CV was < 6% and ICC was > 0.94 for the reproducibility of both FEV1 and PEF measurements. The accuracy of the PiKo-1 device was better for FEV1 (ICC = 0.98) than for PEF (ICC = 0.90). The Spirotel device had similar results for FEV1 and PEF (ICC = 0.95). The Mini-Wright device had the lowest accuracy (ICC = 0.87), particularly for PEF values < 500 L/min. CONCLUSIONS These low-cost and easy-to-use electronic monitoring devices showed a very good reproducibility and were in agreement with the pneumotachograph. Therefore, the PiKo-1 and Spirotel devices seem adequate for both screening and monitoring. However, prospective studies are still needed to assess their long-term reproducibility and usability and, particularly, the effects on the improvement of respiratory care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lung Function Monitoring; A Randomized Agreement Study

OBJECTIVE To determine the agreement between devices and repeatability within devices of the forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF) and forced expiratory flow at 50% of FVC (FEF50) values measured using the four spirometers included in the study. METHODS 50 (24 women) participants (20-64 years of age) completed maximum forced expiratory...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

Effect of Incentive Spirometry on Pulmonary Function Tests in Patients Undergoing Hemodialysis: A Randomized Clinical Trials

Objectives: This study was aimed to determine the Effect effect of incentive spirometry on pulmonary function tests in patients undergoing hemodialysis. Methods: This study was a randomized clinical trial conducted in on hemodialysis patients. The obtained Data were collected from 26 patients in the experimental and 26 patients in the control group. In The the control group, patients received ...

متن کامل

Theoretical and Computational Evaluation of the Use of Molecular Nanoelectronic Technology in Targeted Monitoring of Electrical Brain Waves to Predict Some Neuro-cerebral Attacks

Abstract Background and Objectives: Today, it is expected that by using molecular nanoelectronic, the symptoms emitted from neurons will be studied. Many studies show that abnormalities in the normal functioning of brain cells can lead to neurological attacks. One of the most common brain system defects is epileptic seizures. In this case, due to the electrical discharge of a group of neurons,...

متن کامل

Assessment of accuracy and applicability of a new electronic peak flow meter and asthma monitor.

The aim of this study was to assess the accuracy and applicability of a portable electronic peak flow meter combined with an asthma monitor (AM1, Jaeger, Germany) which measures peak expiratory flow (PEF), forced expiratory volume in one second (FEV1) and forced vital capacity (FVC). The technical accuracy in PEF, FEV1 and FVC measurement was tested according to American Thoracic Society (ATS) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 128 3  شماره 

صفحات  -

تاریخ انتشار 2005