A fully automated, continuous-flow radioimmunoassay for methotrexate.
نویسندگان
چکیده
We describe a fully automated continuous-flow radioimmunoassay for methotrexate. [125I]Histamine-labeled methotrexate was used as tracer. Anti-methotrexate serum was coupled to a magnetizable solid-phase and the bound and free fractions were separated with an electromagnetic field. The assay is precise (CV less than 2.5%) and rapid (30 samples per hour), incubation volume is small (about 160 micro L), and incubation brief (10 min). The accurate timing inherent in the system obviates the need to attain equilibrium, so that assay of each sample takes only 15 min. The assay is sensitive (1--100 microgram/L). There is no significant carryover between samples of high and low concentration. Results by the automated method correlated well with those by both a manual assay in which the same reagents and separation technique are used (r - 0.99) and a competitive protein-binding assay (r = 0.96).
منابع مشابه
Performance assessment of the GammafloTM automated radioimmunoassay system by assaying for digoxin.
We report an evaluation of the GammafloTM automated continuous-flow radioimmunoassay instrument in which we used a digoxin assay to assess system performance. System operation was based on combined continuous-flow and column-chromatographic techniques. No drift or carryover was detectable in 180 within-assay consecutive determinations performed at a rate of 42 determinations per hour (5 h of co...
متن کاملRetrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system
Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...
متن کاملEvaluation of an automated radioimmunoassay for serum cortisol.
The performance characteristics are reported for a serum cortisol assay using the GAMMAFLO Automated Assay System, an automated continuous-flow system for radioimmunoassay (RIA). This automated system utilizes a combination of continuous-flow methodology and column chromatography techniques. The cortisol assay studied had a standard curve range of 10.0 to 500 microgram per L. The intra-assay an...
متن کاملAutomated continuous-flow radioimmunoassay for salivary estriol.
We have automated a radioimmunoassay for salivary estriol by using the "Southmead" continuous-flow system. The assay, based on a well-validated manual assay, involves a Sepharose-coupled antiserum and an 125I-radioligand. The antibody-bound and free radioligand fractions are separated by on-line filtration. Performance of the automated assay has been reliable during six months of regular use, a...
متن کاملContinuous-flow enzyme immunoassay for thyroxine in serum.
We have evaluated a fully automated thyroxine assay involving the use of a homogeneous enzyme assay and a Technicon AutoAnalyzer II continuous flow system. Comparison by regression analysis with a thyroxine radioimmunoassay kit method gave a slope of 0.82 and a y-intercept of 7.81 micrograms/L (SE 0.86 microgram/L, r = 0.95). Within-run precision yielded CVs of 1.0-6.1%, between-day CVs were 2....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 26 1 شماره
صفحات -
تاریخ انتشار 1980