New calculations for internal dosimetry of beta-emitting radiopharmaceuticals.

نویسندگان

  • M Zankl
  • N Petoussi-Henss
  • T Janzen
  • H Uusijärvi
  • H Schlattl
  • W B Li
  • A Giussani
  • C Hoeschen
چکیده

The calculation of absorbed dose from internally incorporated radionuclides is based on the so-called specific absorbed fractions (SAFs) which represent the fraction of energy emitted in a given source region that is absorbed per unit mass in a specific target organ. Until recently, photon SAFs were calculated using MIRD-type mathematical phantoms. For electrons, the energy released was assumed to be absorbed locally ('ICRP 30 approach'). For this work, photon and electron SAFs were derived with Monte Carlo simulations in the new male voxel-based reference computational phantom adopted by the ICRP and ICRU. The present results show that the assumption of electrons being locally absorbed is not always true at energies above 300-500 keV. For source/target organ pairs in close vicinity, high-energy electrons escaping from the source organ may result in cross-fire electron SAFs in the same order of magnitude as those from photons. Examples of organ absorbed doses per unit activity are given for (18)F-choline and (123)I-iodide. The impact of the new electron SAFs used for absorbed dose calculations compared with the previously used assumptions was found to be small. The organ dose coefficients for the two approaches differ by not more than 6 % for most organs. Only for irradiation of the urinary bladder wall by activity in the contents, the ICRP 30 approach presents an overestimation of approximately 40-50%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of Iranian Adult Female Reference Phantom for Internal Dosimetry Calculations

Estimation of organ doses in diagnostic and therapeutic nuclear medicine procedures is an area of particular concern for radiation protection, in all over the world. The stylized computational phantoms have contributed significantly to radiation dosimetry in nuclear medicine; however, their simplified treatment of human anatomy is being criticized. Due to the fact that the ICRP adult reference ...

متن کامل

Cellular dosimetry of beta emitting radionuclides-antibody conjugates for radioimmunotherapy

Introduction: The choice of optimal radionuclides for radioimmunotherapy depends on several factors, especially the radionuclide and antibody. The dosimetric characteristics of a non-internalizing and an internalizing monoclonal antibody (MAb) labeled with beta emitting radionuclides were investigated. Methods: Using Geant4-DNA Monte Carlo simulation, we ...

متن کامل

Internal Radiation Dose and Modeling Codes in Nuclear Medicine: A Fresh Look at Old Problems

With these codes, basic dose calculations could be made in seconds instead of hours. Another purpose of these codes was to help standardize dose calculations using recognized models, phantoms, and dosimetry techniques. In nuclear medicine community, the aim is to perform calculations to obtain dose estimates for various organs of the body once the kinetics of a radiopharmaceutical agent is esta...

متن کامل

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 139 1-3  شماره 

صفحات  -

تاریخ انتشار 2010