Temporal artery thermometer use in the prehospital setting.

نویسندگان

  • Erica Carleton
  • Brenda Fry
  • Ashlee Mulligan
  • Ali Bell
  • Cory Brossart
چکیده

OBJECTIVES Prehospital vital signs are an important and required component of patient assessment. We compared the temporal artery thermometer (TAT) to the digital thermometer currently used in our emergency medical service (EMS) system and then to the digital thermometer used in the emergency department. The primary objective of this study was to assess the usefulness of the TAT in the prehospital setting. Other outcomes of interest included whether extraneous factors or cold ambient temperatures affected the TAT readings and paramedic satisfaction with the TAT. METHODS This was a prospective, observational study. Patient temperature was taken by EMS personnel with both the digital thermometer and the TAT, and a chart review was conducted on a sample of these patients to compare the TAT to the emergency department digital thermometer. RESULTS A total of 818 patients had their temperatures taken with both thermometers in the prehospital setting. The relationship between the TAT and digital thermometer measurement was positive and moderate; however, there was poor agreement between the two devices. Sixty-nine charts were reviewed, and a positive correlation was found between the TAT and the emergency department digital thermometer, with good agreement between the two devices. No extraneous factors were found to have a noticeable effect on the temperature measurements; the TAT performed well in cold weather, and the EMS personnel reported it to be easy to use. CONCLUSION The TAT appears to be a suitable alternative to digital thermometers currently used in many EMS systems. The paramedics involved in this study liked the TAT better than the in-ambulance digital thermometer and believed it to be more accurate. Further research on this topic is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison sensitivity and specificity temporal artery temperature measurement with axillary and nasopharyngeal methods in adult

      Aims: temporal artery thermometers (TAT) of new tools for measuring body temperature, few studies have been conducted to evaluate the accuracy and reliability of thermometers and is still uncertain accuracy and reliability this thermometers.This study to evaluate the accuracy of the two methods of measuring body temperature by the thermometer axillary and temporal artery compared with nas...

متن کامل

Accuracy of a noninvasive temporal artery thermometer for use in infants.

OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...

متن کامل

Prehospital Lactate Measurement by Emergency Medical Services in Patients Meeting Sepsis Criteria

INTRODUCTION We aimed to pilot test the delivery of sepsis education to emergency medical services (EMS) providers and the feasibility of equipping them with temporal artery thermometers (TATs) and handheld lactate meters to aid in the prehospital recognition of sepsis. METHODS This study used a convenience sample of prehospital patients meeting established criteria for sepsis. Paramedics rec...

متن کامل

Accuracy of temporal artery thermometry in neonatal intensive care infants.

PURPOSE To determine the accuracy of temporal artery and axillary temperatures and the discomfort level of stable neonates during temperature measurement. SUBJECTS Convenience sample of neonates between the ages of 32 and 40 weeks' gestation cared for in an isolette or crib. DESIGN A method-comparison design was used to compare different methods for noninvasive temperature monitoring (infra...

متن کامل

Insufficiency in a new temporal-artery thermometer for adult and pediatric patients.

UNLABELLED SensorTouch is a new noninvasive temperature monitor and consists of an infrared scanner that detects the highest temperature on the skin of the forehead, presumably over the temporal artery. The device estimates core temperature (T(core)). We tested the hypothesis that the SensorTouch is sufficiently precise and accurate for routine clinical use. We studied adults (n = 15) and child...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • CJEM

دوره 14 1  شماره 

صفحات  -

تاریخ انتشار 2012