Constraints on Mantle Electrical Conductivity from Field and Laboratory Measurements
نویسنده
چکیده
A global geomagnetic response function, sensitive to the average radial electrical conductivity structure of Earth’s mantle to depths of at least 1800 km, is obtained by averaging published, single-site response functions estimated at periods between 10 – 10 seconds from magnetic observatory records. Although the error bars on the global response function are mostly smaller than 5%, Parker’s D algorithm demonstrates compatibility with a one-dimensional model, both in terms of magnitude and distribution of data residuals. Smooth models in the sense of minimum first and second derivatives of log(conductivity) with log(depth) show conductivities increasing from 0.01 S/m 200 km deep to 2 S/m at a depth of 2000 km. Geotherms inferred from these conductivities using a laboratory model for the temperature dependence of dry subsolidus olivine yield temperatures of 1750◦C at a depth of 410 km; hotter than the 1400◦C for this depth inferred from published values for the equilibrium boundary of the olivine α → α+β transition. Inclusion of a sharp jump in conductivity at the 660 km seismic discontinuity lowers the electrogeotherm to 1600◦C at 410 km, while an explicit penalty on the conductivity at this depth demonstrates that a temperature of 1400◦ is compatible with the global response function if 1000 S of additional conductance is included above 200 km. The electrical conductivity below the jump at 660 km is 1 S/m increasing to 2 S/m at 2000 km, in excellent agreement with recent diamond anvil measurements of lower mantle materials. Extension of the global response to higher frequencies is possible using data from magnetic satellites. One such study is shown to be in general agreement with the averaged response.
منابع مشابه
Water in cratonic lithosphere: Calibrating laboratory-determined models of electrical conductivity of mantle minerals using geophysical and petrological observations
[1] Measurements of electrical conductivity of “slightly damp” mantle minerals from different laboratories are inconsistent, requiring geophysicists to make choices between them when interpreting their electrical observations. These choices lead to dramatically different conclusions about the amount of water in the mantle, resulting in conflicting conclusions regarding rheological conditions; t...
متن کاملCan in situ measurements of mantle electrical conductivity be used to infer properties of partial melts?
[1] Constraints on bulk conductivity from magnetotelluric measurements and petrological analyses of late Quaternary peridotite xenoliths from the southern Sierra Nevada allow evaluation of models commonly used to relate electrical conductivity to the physical and chemical state of the upper mantle. In these models, two conductive melts (basalt and sulfide) are embedded in a resistive matrix. Bo...
متن کاملThe Electrical Conductivity and Thermal Profile of the Earth' mid-Mantle
Electrical conductivity in the Earth's mantle is sensitive to temperature and chemical environment. Recent laboratory measurements of electrical conductivity are combined with candidate mantle geotherms to produce synthetic electrical conductivity profiles. These profiles are used to forward model the Earth's geomagnetic response function C, results of which are compared with the observed globa...
متن کاملWater and the Electrical Conductivity of the Lunar Mantle
Introduction. The electrical conductivity of minerals increases with temperature and impurity content [e.g., 1]. Aluminum in orthopyroxene is one such impurity that has been invoked to fit the electrical conductivity of the deep interior of the Moon while maintaining subsolidus temperatures [2-4]. However, the required bulk alumina abundance in pyroxene is comparable to that inferred for the en...
متن کاملDehydration of chlorite explains anomalously high electrical conductivity in the mantle wedges
Mantle wedge regions in subduction zone settings show anomalously high electrical conductivity (~1 S/m) that has often been attributed to the presence of aqueous fluids released by slab dehydration. Laboratory-based measurements of the electrical conductivity of hydrous phases and aqueous fluids are significantly lower and cannot readily explain the geophysically observed anomalously high elect...
متن کامل