Local determinants of thrombus formation following sirolimus-eluting stent implantation assessed by optical coherence tomography.

نویسندگان

  • Hiromasa Otake
  • Junya Shite
  • Junya Ako
  • Toshiro Shinke
  • Yusuke Tanino
  • Daisuke Ogasawara
  • Takahiro Sawada
  • Naoki Miyoshi
  • Hiroki Kato
  • Bon-Kwon Koo
  • Yasuhiro Honda
  • Peter J Fitzgerald
  • Ken-ichi Hirata
چکیده

OBJECTIVES We conducted this study to assess the prevalence and determinants of subclinical thrombus after sirolimus-eluting stent (SES) implantation. BACKGROUND Angioscopic analyses have demonstrated the presence of thrombus is more common than the clinical incidence of SES thrombosis. METHODS Fifty-three patients (53 lesions) underwent 6-month follow-up optical coherence tomography. A stent eccentricity index ([SEI] minimum/maximum stent diameter) was determined in each cross section. To evaluate unevenness of neointimal thickness, a neointimal unevenness score ([NUS] maximum neointimal thickness in the cross section/average neointimal thickness of the same cross section) was calculated for each cross section. Average SEI and NUS were calculated for each stent. Major adverse cardiac events were defined as a composite of death, myocardial infarction, and target vessel revascularization. RESULTS Fourteen cases of thrombus (26%) were detected by optical coherence tomography (thrombus: n = 14 vs. nonthrombus: n = 39). The percentage of thrombus was associated with longer stents (36.4 +/- 20.2 mm vs. 25.1 +/- 9.8 mm; p = 0.008), a larger number of uncovered struts (17 +/- 16 vs. 8 +/- 11; p = 0.03), smaller average SEI (0.89 +/- 0.04 vs. 0.92 +/- 0.03; p = 0.001), and greater average NUS (2.22 +/- 0.24 vs. 2.00 +/- 0.33; p = 0.03). A significant relationship existed between average SEI and average NUS (p < 0.0001, R = 0.68), and between average SEI and the number of uncovered struts (p < 0.0006, R = 0.46). There was no significant difference in major adverse cardiac events during follow-up (median: 485 days, 7.1% vs. 12.8%; p > 0.99). CONCLUSIONS Longer stents and greater asymmetric stent expansion may be important determinants of thrombus formation after SES implantation. In this small cohort, the presence of thrombus did not increase the risk of major adverse cardiac events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical coherence tomography findings in lesions after sirolimus-eluting stent implantation with peri-stent contrast staining.

BACKGROUND We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. METHODS AND RESULTS Between May 2008 an...

متن کامل

Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography.

BACKGROUND Late vascular responses after implantation of drug-eluting stents may play a key role in steadily increasing occurrence of very late stent thrombosis have not yet been fully investigated in human beings. METHODS AND RESULTS Serial optical coherence tomography observations at 2 and 4 years were collected for 17 patients treated with 21 sirolimus-eluting stents. Corresponding 376 cro...

متن کامل

Optical coherence tomography evaluation of zotarolimus-eluting stents at 9-month follow-up: comparison with sirolimus-eluting stents

OBJECTIVE To evaluate the vascular response at 9 months after zotarolimus-eluting stent (ZES; Endeavor) implantation using optical coherence tomography (OCT). These findings were compared with those after implantation of a sirolimus-eluting stent (SES; Cypher Select). DESIGN Cross-sectional observational study with prospective OCT registry. SETTING Nine months after ZES or SES implantation....

متن کامل

Comparison of neointimal coverage of sirolimus-eluting stents and paclitaxel-eluting stents using optical coherence tomography at 9 months after implantation.

BACKGROUND The differences between using sirolimus-eluting stents (SESs) and paclitaxel-eluting stents (PESs) in the vascular response at 9 months after implantation were examined with optical coherence tomography (OCT). METHODS AND RESULTS OCT was carried out in 33 SESs [33 patients, 19 with acute coronary syndrome (ACS) and 14 with stable angina pectoris (SAP)] and 27 PESs (27 patients, 15 ...

متن کامل

Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation.

Novel polymer-free drug-eluting stents have been developed to reduce polymer-related adverse events. However, neointimal coverage after polymer-free DES implantation is unclear and validation between optical coherence tomography (OCT) and histology is required. Sixteen polymer-free sirolimus-eluting stents were randomly implanted into coronary arteries of 8 normal swine. OCT and histological me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 2 5  شماره 

صفحات  -

تاریخ انتشار 2009