Dosimetry Studies on a Fetus Model Combining Medical Image Information and a Synthetic Woman Body

نویسندگان

  • L. Bibin
  • J. Anquez
  • A. Hadjem
  • E. Angelini
  • J. Wiart
  • I. Bloch
چکیده

Wireless systems are increasingly used and the electromagnetic fields (EMF) generated by these systems have induced a large public concern regarding potential sanitary effects, in particular on children and fetus during pregnancy. Few works have been performed to analyze the fetus exposure but additional studies are still needed, based on precise anatomical models. In this paper, we propose a new method to assess the fetus exposure, based on realistic anatomical models built from 3D MRI images at different gestational ages. The whole body specific absorption rate (SAR) and the maximum SAR over 10 grams have been estimated using finite differences in time domain (FDTD) simulation methods for five fetuses at different ages. Results show that the local and the whole body SAR are lower in the fetus than in the mother and that they depend on position and morphology but not on gestational age. Keywords— “Dosimetry”, “3D Modeling”, “Segmentation”, “Fetus”, “Medical Imaging”.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comprehensive tool for image-based generation of fetus and pregnant women mesh models for numerical dosimetry studies.

Fetal dosimetry studies require the development of accurate numerical 3D models of the pregnant woman and the fetus. This paper proposes a 3D articulated fetal growth model covering the main phases of pregnancy and a pregnant woman model combining the utero-fetal structures and a deformable non-pregnant woman body envelope. The structures of interest were automatically or semi-automatically (de...

متن کامل

Utero-Fetal Unit and Pregnant Woman Modeling Using a Computer Graphics Approach for Dosimetry Studies

Potential sanitary effects related to electromagnetic fields exposure raise public concerns, especially for fetuses during pregnancy. Human fetus exposure can only be assessed through simulated dosimetry studies, performed on anthropomorphic models of pregnant women. In this paper, we propose a new methodology to generate a set of detailed utero-fetal unit (UFU) 3D models during the first and t...

متن کامل

Physics-Based Modeling of the Pregnant Woman

High quality obstetric images have become readily available with fast magnetic resonance imaging protocols or new 3D ultrasound probes. These obstetric images provide detailed information which can be used to create realistic models of the fetus at different stages of gestation. Unfortunately, the anatomy of the mother is only partially visible in the obstetric images and a full model of the pr...

متن کامل

FEMONUM: A Framework for Whole Body Pregnant Woman Modeling from Ante-Natal Imaging Data

Anatomical models of pregnant women can be used in several applications such as numerical dosimetry to assess the potential effects of electromagnetic fields on biological tissues, or medical simulations for delivery planning. Recent advances in medical imaging have enabled the generation of realistic and detailed models of human beings. This paper describes FEMONUM, a complete methodological f...

متن کامل

Skin in vivo Dosimetry in Radiotherapy

Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009