Comparison of the Abbott realtime human immunodeficiency virus type 1 (HIV-1) assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 test: workflow, reliability, and direct costs.

نویسندگان

  • Cari R Sloma
  • Jeffrey J Germer
  • Tara M Gerads
  • Jayawant N Mandrekar
  • P Shawn Mitchell
  • Joseph D C Yao
چکیده

The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results (r = 0.95) among clinical specimens, with a mean difference of -0.34 log(10) copies/ml. Testing of healthy donor plasma specimens yielded "target not detected" results by ART, with "HIV-1 RNA detected, <40 copies/ml" results for 3.3% (3 of 90 samples) of these specimens by CTM. Both the m2000sp/m2000rt (ART) and docked CAP/CTM96 (CTM) instrument systems were capable of operating with continuous, uninterrupted workflow. When daily maintenance and cleaning were included, ART and CTM run durations (5 h 52 min and 6 h 4 min, respectively) and hands-on times (53 min and 46 min, respectively) were similar for a run batch size of 24. While ART was more flexible in terms of run batch size, CTM required fewer user interventions and consistently produced higher specimen throughput rates at 8, 16, and 24 h. Assay run failure rates were 6.3% (1 of 16 runs) and 4.2% (1 of 24 runs) for ART and CTM, respectively (P = 1.000), with invalid specimen result rates of 1.0% (5 of 495 specimens) and 2.8% (11 of 399 specimens), respectively (P = 0.073). Direct reagent and consumable costs for each assay were comparable (difference of <10%). In selecting an assay for implementation, laboratories should consider how various assay and instrument features might impact laboratory operation and patient care.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

The implementation of antiretroviral therapy demands the need for increased access to viral load (VL) monitoring. Newer real-time VL testing technologies are faster and have larger dynamic ranges and fully automated extraction to benefit higher throughputs in resource-poor environments. The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay was evaluated as a new option for testi...

متن کامل

Performance evaluation of the new Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test version 2.0 for quantification of human immunodeficiency virus type 1 RNA.

Despite FDA approval and CE marking of commercial tests, manufacturer-independent testing of the technical aspects of newly developed tests is important. To evaluate the analytical performance and explore the clinical applicability of the new Roche COBAS AmpliPrep COBAS TaqMan HIV-1 test, version 2.0 (CAP/CTM v2.0), platform comparison was performed with the Roche CAP/CTM test, version 2.0, the...

متن کامل

Use of active surveillance cultures in intensive care units.

3. Katsoulidou A, Petrodaskalaki M, Sypsa V, et al. Evaluation of the clinical sensitivity for the quantitation of human immunodeficiency virus type 1 RNA in plasma: comparison of the new Cobas TaqMan HIV-1 with three current HIV-RNA assays–LCx HIV RNA quantitative, Versant HIV-1 RNA 3.0 (bDNA) and Cobas Amplicor HIV-1 Monitor v1.5. J Virol Methods 2006; 131:168–74. 4. Damond F, Roquebert B, Be...

متن کامل

Large-scale comparison of Roche Cobas AmpliPrep/Cobas TaqMan and Abbott RealTime HIV assays.

Significant underquantitation of HIV RNA has been reported with the Roche Cobas AmpliPrep/Cobas TaqMan HIV Test (Version 1) compared to other assays. However, these studies have generally involved limited numbers of samples from select patient populations or analysis of samples that were undetectable in the TaqMan assay. Random plasma samples submitted from throughout the United States for HIV ...

متن کامل

Evaluation of the Abbott RealTime HBV DNA assay and comparison to the Cobas AmpliPrep/Cobas TaqMan 48 assay in monitoring patients with chronic cases of hepatitis B.

The new Abbott RealTime hepatitis B virus (HBV) assay was compared to the Cobas AmpliPrep/Cobas TaqMan assay with 128 serum samples from patients with chronic hepatitis B. There was an excellent correlation (r = 0.961) between the two assays, with the Abbott RealTime test showing at least equivalent sensitivity and a slightly wider dynamic range than the Cobas TaqMan assay. By coupling high sen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 47 4  شماره 

صفحات  -

تاریخ انتشار 2009