Airtraq(®) laryngoscope-assisted fiberoptic bronchoscope intubation in a child with Pierre-Robin sequence: a case report.

نویسندگان

  • Shuang Zhang
  • Mingliang Yi
چکیده

We present a new strategy method of combining use of Airtraq(®) and fiberoptic bronchoscope (FOB) for tracheal intubation in 3-year-old child with Pierre-Robin sequence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of Airtraq laryngoscope versus Macintosh laryngoscope and fiberoptic bronchoscope by experienced anesthesiologists.

OBJECTIVE The aim was to compare the hemodynamic parameters, intubation times, upper airway trauma and postoperative sore throat scores of the patients with normal airway anatomy, intubated with the Airtraq, Macintosh laryngoscope and fiberoptic bronchoscope, by experienced anesthesiologists. METHODS Ninety patients, scheduled to undergo elective surgery under general anesthesia were randomly...

متن کامل

Airway management for intubation in newborns with Pierre Robin sequence.

OBJECTIVES/HYPOTHESIS To review airway management in Pierre Robin sequence (PRS) newborns undergoing general anesthesia and to determine if endotracheal intubation is safe in this population. STUDY DESIGN Case series and retrospective chart review at a tertiary children's hospital. METHODS PRS newborns who underwent endotracheal intubation or other airway intervention before 3 months of age...

متن کامل

Endotracheal intubation using the Airtraq optical laryngoscope when the glottis is off-center of the viewfinder: are the options of optimization exhausted?

he leading cause of anesthesia-related injury is the nability to intubate the trachea and secure the airway.1 mprovements in video and optical laryngoscopy have llowed to obtain an indirect view of the glottis in a ore simple way but sometimes this advantage occurs ogether with a difficult or impossible endotracheal tube ETT) insertion.2 This is because indirect techniques do not equire the ali...

متن کامل

Management of the Difficult Paediatric Airway with a Simple Fiberoptic-Assisted Laryngoscope: A Report of Two Cases with Pierre Robin and Patau's (Trisomy 13) Syndrome.

Airway management of children with congenital craniofacial anomalies is a challenge for paediatric anaesthesiologists. We do not have any video-assisted airway device in our department for difficult paediatric intubations. We decided to attach a regular fiberoptic (outer diameter; 3.7 mm, Karl Storz, Germany) scope to a conventional Macintosh Laryngoscope (size 1). We describe two cases of Pier...

متن کامل

Combined use of an Airtraq® optical laryngoscope, Airtraq video camera, Airtraq wireless monitor, and a fibreoptic bronchoscope after failed tracheal intubation.

Combined Use of an Airtraq Optical Laryngoscope, Airtraq Video Camera, Airtraq Wireless Monitor, and a Fibreoptic Bronchoscope After Failed Tracheal Intubation Can J Anesth/J Can Anesth (2011) 58:411–412 Manuel Angel Gomez-Rıos, MD Laura Nieto Serradilla, MD Complejo Hospitalario Universitario A Coruna Spain This case report presents the simultaneous use of an Airtraq optical laryngoscope, Airt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of clinical and experimental medicine

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 2015