Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence.

نویسندگان

  • D J Atkinson
  • R R Edelman
چکیده

Six healthy volunteers and three patients with cardiac anomalies were studied in a comparison of segmented turboFLASH (fast low-angle shot) cine, a method of magnetic resonance imaging that permits an entire series of high-resolution cine images to be obtained in one breath hold, with standard cine. Segmented turboFLASH uses a gradient-echo sequence designed for short imaging times in combination with a segmented data acquisition method. Presaturation pulses were applied to eliminate the blood pool signal; the signal-to-noise ratio was assessed with a phantom. Standard hardware and image reconstruction methods were used. The breath-hold images consistently showed reduced ghosting and blurring from respiration. Because a very short echo time was used, segmented turboFLASH was relatively insensitive to dephasing caused by local field disturbances or flow. The authors conclude that, by reducing imaging times and eliminating respiratory artifact, segmented turboFLASH can be useful for performing cine studies of the heart and great vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

STRUCTURE AND FUNCTION Rapid Evaluation of Right and Left Ventricular Function and Mass Using Real-Time True-FISP Cine MR Imaging Without Breath-Hold: Comparison with Segmented True-FISP Cine MR Imaging with Breath-Hold

Purpose. To evaluate the accuracy of cardiac function measured with real-time true fast imaging with steady-state precession (True-FISP) cine without breath-hold compared with those measured from segmented True-FISP cine with breath-hold. Methods. Eighteen consecutive patients and six healthy volunteers were enrolled in the study group. Both realtime multislice True-FISP cine imaging without br...

متن کامل

Breath - hold signal loss sequence for the qualitative assessment of blood flow disturbances in cardiovascular

The development of a breath-hold segmented FLASH sequence for the visualisation of signal loss in areas of complex blood flow is described. Both velocity sensitised and acceleration sensitised sequences were developed and compared with a conventional non-segmented TE14 sequence (taking approximately 2 minutes to acquire) in 8 subjects with valvular heart disease. All three sequences resulted in...

متن کامل

A Comparative Study of 3-D Conformal Radiotherapy Treatment Plans with and Without Deep Inspiration Breath-Hold Technique for Left-Sided Breast Cancer

Introduction: The rate of cardiac diseases have increased among patients who underwent radiotherapy for left-sided breast cancer. The study’s aim was evaluate the dose to organs at risk in free-breathing 3-dimensional conformal (FB-3DCRT) against 3-dimensional conformal deep inspiration breath-hold (3DCRT-DIBH) in patients with left-sided breast cancer. Ma...

متن کامل

Single breath-hold 3D LGE using stack of spiral trajectory

Background Late gadolinium enhancement (LGE) imaging is the gold standard for noninvasive evaluation of myocardial scar. In the clinical setting, the standard imaging protocol involves a breath-held segmented inversion-prepared 2D Cartesian acquisition at a single location. This breathhold scan is repeated 10 -14 times to cover the entire left ventricle. Although multislice 2D LGE has shown gre...

متن کامل

Equivalence of conventional and fast late gadolinium enhancement (LGE) techniques for quantitative evaluation of fibrosis in ischemic and non-ischemic cardiac disease - Save the Time!

Methods Patients with myocardial infarction (n = 45), myocarditis (n = 25) or hypertrophic cardiomyopathy (HCM) (n = 15) were prospectively enrolled. After administration of gadolinium contrast agent, LGE images were acquired ECG-gated in short axis slices (slice thickness 7 mm, no gap) using 4 different LGE sequences: (1) conventional segmented 2D phase-sensitive inversion recovery in single-s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 178 2  شماره 

صفحات  -

تاریخ انتشار 1991