Immediate post-partum insertion of intrauterine devices: a Cochrane review.

نویسندگان

  • D Grimes
  • K Schulz
  • H van Vliet
  • N Stanwood
چکیده

BACKGROUND Insertion of an intrauterine device (IUD) immediately after delivery is appealing for several reasons. The woman is known not to be pregnant, her motivation for contraception may be high and the setting may be convenient for both the woman and her provider. However, the risk of spontaneous expulsion may be unacceptably high. The objective of this study was to assess the efficacy and feasibility of IUD insertion immediately after expulsion of the placenta. Our a priori hypothesis was that this practice is safe, but associated with higher expulsion rates than interval IUD insertion. METHODS We used Medline, Popline, Embase, and Cochrane Controlled Trials Register computer searches, supplemented by review articles and contact with investigators. We sought all randomized controlled trials that had at least one treatment arm that involved immediate post-partum (within 10 min of placental expulsion) insertion of an IUD. Comparisons could include different IUDs, different insertion techniques, immediate versus delayed post-partum insertion, or immediate versus interval insertion (unrelated to pregnancy). Studies could include either vaginal or Caesarean deliveries. We evaluated the methodological quality of each report and sought to identify duplicate reporting of data from multicentre trials. We abstracted data onto data collection forms. Principal outcome measures included pregnancy, expulsion and continuation rates. Because the trials did not have uniform interventions, we were unable to aggregate them in a meta-analysis. RESULTS We found no randomized controlled trials that directly compared immediate post-partum insertion with either delayed post-partum or interval insertion. Modifications of existing devices, such as adding absorbable sutures or additional appendages, did not appear beneficial. Most studies showed no important differences between insertions done by hand or by instruments. Lippes Loops and Progestasert devices did not perform as well as copper devices. CONCLUSIONS Immediate post-partum insertion of IUDs appeared safe and effective, though direct comparisons with other insertion times were lacking. Advantages of immediate post-partum insertion include high motivation, assurance that the woman is not pregnant, and convenience. However, expulsion rates appear to be higher than with interval insertion. The popularity of immediate post-partum IUD insertion in countries as diverse as China, Mexico and Egypt support the feasibility of this approach. Early follow-up may be important in identifying spontaneous IUD expulsions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post-placental intrauterine device insertion - A five year experience at a tertiary care centre in north India

BACKGROUND & OBJECTIVES In view of high rate of unintended pregnancy in our country, particularly in post-partum women, there is a need for reliable, effective, long-term contraception such as intrauterine device (IUD) in post-partum women. The present study was planned to evaluate the safety and efficacy of immediate post-partum IUD insertion in women delivering vaginally or by caesarian secti...

متن کامل

Intrauterine device insertion during the postpartum period: a systematic review.

BACKGROUND Insertion of an intrauterine device (IUD) at different times or by different routes during the postpartum period may increase the risk of complications. METHODS We searched Medline, Lilacs and Cochrane Collaboration databases for articles in any language, between database inception until December 2008, which compared outcomes of postpartum IUD insertion time intervals. Search terms...

متن کامل

Experience on Awareness, Acceptability, Safety, Efficacy, Complications and Expulsion of Post- partum Intrauterine Contraceptive Device Insertion

Background: Purpose: This study was conducted to evaluate the awareness, acceptance, safety, efficacy, complications and expulsion rate of Post-partum Intrauterine Contraceptive Device (PPIUCD) insertion among pregnant women in a tertiary care center. Materials and Methods: This is a retrospective analytical study conducted in S.C.B Medical College and Hospital, Cuttack, Odisha, over a period o...

متن کامل

Immediate postpartum insertion of intrauterine device for contraception.

BACKGROUND Women who want to start intrauterine contraception (IUC) during the postpartum period might benefit from IUC insertion immediately after delivery. Postplacental insertion greatly reduces the risk of subsequent pregnancy and eliminates the need for a return visit to start contraception. Without the option of immediate insertion, many women may never return for services or may adopt le...

متن کامل

The challenge to solve the expulsion problem of immediate postplacental insertion of IUD.

We have read with interest the article by Cohen et al. entitled “Twelve-month contraceptive continuation and repeat pregnancy among young mothers choosing post-delivery contraceptive implants or postplacental intrauterine devices” [1]. What strikes us time and time again in articles published on postplacental/postpartum insertion of IUDs is the unacceptable high total expulsion as well as the h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Human reproduction

دوره 17 3  شماره 

صفحات  -

تاریخ انتشار 2002