Uptake Index of 123I-metaiodobenzylguanidine Myocardial Scintigraphy for Diagnosing Lewy Body Disease

نویسندگان

  • Yoshito Kamiya
  • Satoru Ota
  • Shintaro Okumiya
  • Kosuke Yamashita
  • Akihiro Takaki
  • Shigeki Ito
چکیده

OBJECTIVES Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson's disease (PD) and dementia with Lewy bodies (DLB). The heart-to-mediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson's plus syndromes and Alzheimer's disease. Although this ratio is useful for distinguishing LBD from non-LBD, it fluctuates depending on the system performance of the gamma cameras. Therefore, a new, simple quantification method using 123I-MIBG uptake analysis is required for clinical study. The purpose of this study was to develop a new uptake index with a simple protocol to determine 123I-MIBG uptake on planar images. METHODS The 123I-MIBG input function was obtained from the input counts of the pulmonary artery (PA), which were assessed by analyzing the PA time-activity curves. The heart region of interest used for determining the H/M was used for calculating the uptake index, which was obtained by dividing the heart count by the input count. RESULTS Forty-eight patients underwent 123I-MIBG chest angiography and planar imaging, after clinical feature assessment and tracer injection. The H/M and 123I-MIBG uptake index were calculated and correlated with clinical features. Values for LBD were significantly lower than those for non-LBD in all analyses (P<0.001). The overlapping ranges between non-LBD and LBD were 2.15 to 2.49 in the H/M method, and 1.04 to 1.22% in the uptake index method. The diagnostic accuracy of the uptake index (area under the curve (AUC), 0.98; sensitivity, 96%; specificity, 91%; positive predictive value (PPV), 90%; negative predictive value (NPV), 93%; and accuracy, 92%) was approximately equal to that of the H/M (AUC, 0.95; sensitivity, 93%; specificity, 91%; PPV, 90%; NPV, 93%; and accuracy, 92%) for discriminating patients with LBD and non-LBD. CONCLUSION A simple uptake index method was developed using 123I-MIBG planar imaging and the input counts determined by analyzing chest radioisotope angiography images of the PA. The diagnostic accuracy of the uptake index was approximately equal to that of the H/M for discriminating patients with LBD and non-LBD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Uptake index of 123I-metaiodobenzylguanidine myocardial scintigraphy for diagnosing Lewy body disease

Objective(s): Iodine-123 metaiodobenzylguanidine (123I-MIBG) myocardial scintigraphy has been used to evaluate cardiac sympathetic denervation in Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies (DLB). The heart-tomediastinum ratio (H/M) in PD and DLB is significantly lower than that in Parkinson’s plus syndromes and Alzheimer’s disease. Although this ra...

متن کامل

Development of an 123I-metaiodobenzylguanidine Myocardial Three-Dimensional Quantification Method for the Diagnosis of Lewy Body Disease

Objective(s): We recently developed a new uptake index method for 123I-metaiodobenzylguanidine (123I-MIBG) heart uptake measurements by using planar images (radioisotope angiography and planar image) for the diagnosis of Lewy body disease (LBD), including Parkinson’s disease (PD) and dementia with Lewy bodies(DLB). However, the diagnostic accuracy of the uptake index was approximately equal to ...

متن کامل

123I-Metaiodobenzylguanidine Myocardial Scintigraphy in Lewy Body-Related Disorders: A Literature Review

Lewy body-related disorders are characterized by the presence of Lewy bodies and Lewy neurites, which have abnormal aggregations of α-synuclein in the nigral and extranigral areas, including in the heart. (123)I-metaiodobenzylguanidine (MIBG) scintigraphy is a well-known tool to evaluate cardiac sympathetic denervation in the Lewy body-related disorders. MIBG scintigraphy showed low uptake of M...

متن کامل

Reduced cardiac uptake and enhanced washout of 123I-MIBG in pure autonomic failure occurs conjointly with Parkinson's disease and dementia with Lewy bodies.

UNLABELLED The purpose of this study was to investigate myocardial uptake of 123I-metaiodobenzylguanidine (MIBG) in patients with pure autonomic failure (PAF), which has pathologic features in common with idiopathic Parkinson's disease (IPD) and dementia with Lewy bodies (DLB). METHODS Six patients with PAF, 130 with IPD, 21 with DLB, 9 with corticobasal degeneration (CBD), 11 with progressiv...

متن کامل

Cardiac 123I-metaiodobenzylguanidine Scintigraphy in a Patient with Familial Parkinsonism with Parkin Gene Mutation

A decreased cardiac (123)I-metaiodobenzylguanidine ((123)I-MIBG) uptake has been used as a powerful tool to identify Lewy body disease, such as idiopathic parkinson's disease (IPD). We performed cardiac (123)I-MIBG scintigraphy in patient with autosomal recessive juvenile parkinsonism (ARJP) with parkin gene mutation (PARK2). The findings showed normal cardiac (123)I-MIBG uptake. Therefore, alt...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2017