Return to Session SHEATH CIRCULATING CURRENT CALCULATIONS AND MEASUREMENTS OF UNDERGROUND POWER CABLES
نویسندگان
چکیده
In this paper, a calculation method of the sheath circulating current is introduced, taking the different grounding types, laying environment, structural parameters of cables into account. Due to the parameters in practice, the circulating currents in sheath are calculated and measured under the conditions of singlepoint grounding and both-end crossbonded grounding. The possible causes, which lead to high circulating current, are discussed based on the calculation method.
منابع مشابه
Adaptive soil model for real-time thermal rating of underground power cables
This study presents a validated adaptive method intended for real-time thermal rating (RTTR) of underground power cables. The accuracy of the RTTR algorithm, when producing emergency ratings or predictive calculations, strongly depends on the following parameters (which have large uncertainties): correct soil modelling, the proper determination of the soil properties and the accurate estimation...
متن کاملCurrent State of Research at Imperial College London in Rf Harvesting and Inductive Power Transfer
This paper presents simulation and experimental results for ambient RF energy harvesting and Inductive Power Transfer systems. End-to-end and dc-load efficiency measurements and calculations were performed to demonstrate the capabilities of both systems, respectively. An RF spectral survey was conducted across all the 270 underground stations in London. DTV, GSM900, GSM1800 and 3G were selected...
متن کاملUnderground contour (UGC) mapping using potential field, well log and comparing with seismic interpretation in Lavarestan area
Coastal Fars gravimetry project in Fars province was carried out to find the buried salt domes and to determine characteristics of faults in this area. The Lavarestan structure was covered by 4203 gravimetry stations in a regular grid of 1000*250 m. Depth structural model of this anticline made in previous studies was based on geological evidences and structural geology measurements. In order t...
متن کاملOptimal Current Meter Placement for Accurate Fault Location Purpose using Dynamic Time Warping
This paper presents a fault location technique for transmission lines with minimum current measurement. This algorithm investigates proper current ratios for fault location problem based on thevenin theory in faulty power networks and calculation of short circuit currents in each branch. These current ratios are extracted regarding lowest sensitivity on thevenin impedance variations of the netw...
متن کاملCharacterization of 3-strap antennas in ASDEX Upgrade
The response of the local RF current measured at limiters of 3-strap ICRF antenna to variations of power balance and phasing at fICRF=30MHz agrees qualitatively well with EM calculations by TOPICA and RAPLICASOL codes. Measurements of tungsten sputtering yield and DC current at the limiters correlate strongly with the local RF current. In contrast to findings for the 2-strap antennas, values of...
متن کامل