Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation.

نویسندگان

  • K Ruetzler
  • G Grubhofer
  • W Schmid
  • D Papp
  • S Nabecker
  • D Hutschala
  • G Lang
  • H Hager
چکیده

BACKGROUND In several clinical situations, lung separation and single-lung ventilation (SLV) is essential. In these cases, the double-lumen tube (DLT) is the most widely used device. Bronchial blocker such as Univent or Arndt Blocker serves as an alternative. The EZ-Blocker(®) (EZ; AnaesthetIQ B.V., Rotterdam, The Netherlands) is a new device promising to exceed clinical performance of DLT. The aim of this study was to assess the clinical performance of EZ in comparison with conventional left-sided DLT. METHODS Forty adult patients undergoing elective thoracic surgery requiring thoracotomy and SLV were included in this study. The patients were randomly assigned to one of two groups: EZ (combined with conventional 7.5 or 8.5 mm single-lumen tube) or DLT (37 or 39 Fr left-sided DLT). Time for intubation procedure and time to verification of the correct position of EZ or DLT using fibreoptic bronchoscopy (FOB) were recorded. After surgery, a thoracic surgeon rated the quality of collapse of the lung (1-3 on a three-level scale). RESULTS Time for intubation using DLT 85.5 (54.8) s was significantly faster (P<0.001) than using EZ 192 (89.7) s, whereas time for bronchoscopy was not significantly different (P=0.556). Conditions of surgery were rated equally [DLT 1.3 (0.6) vs EZ 1.4 (0.6), P=0.681]. CONCLUSIONS Although time for intubation was longer with the EZ, the device proved to be an efficient and easy-to-use device. The EZ is a valuable alternative device to conventional DLT. Verification of the correct position of the EZ by FOB seems to be obligatory. This study was registered at http://www.clinicaltrials.gov (identifier: NCT01171560).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RESPIRATION AND THE AIRWAY Randomized clinical trial comparing double-lumen tube and EZ-Blocker for single-lung ventilation

Editor’s key points † A new EZ bronchial blocker was compared with double-lumen tube (DLT) for providing single-lung ventilation (SLV). † Forty patients undergoing thoracic surgery were randomized to one of the two groups. † EZ-Blocker (EZ) provided comparable quality of lung collapse to DLT, but took longer for its placement. † EZ will be an efficient alternative for SLV where DLT cannot be us...

متن کامل

Hemodynamic and Humoral Response to Intubation with Double-lumen Endotracheal Tubes Versus Single-lumen Tubes Combined with an Endobronchial Blocker: A Randomized Clinical Trial

Introduction: Insertion of endotracheal tubes, especially large and relatively inflexible double-lumen tubes, provokes cardiovascular and humoral responses which can cause complications. Bronchial blockers, combined with conventional single-lumen tubes (SLT), serve as alternatives to double-lumen tubes (DLT) and may provoke less hemodynamic response. Methods: Forty adults scheduled for elective...

متن کامل

Airway injuries after one-lung ventilation: a comparison between double-lumen tube and endobronchial blocker: a randomized, prospective, controlled trial.

BACKGROUND Vocal cord injuries, postoperative hoarseness, and sore throat are common complications after general anesthesia. One-lung ventilation can be achieved via two techniques: double-lumen endotracheal tube or endobronchial blocker such as the Arndt blocker. The current study was designed to assess the impact of these techniques for one-lung ventilation on the incidence and severity of po...

متن کامل

The Papworth BiVent tube: a feasibility study of a novel double-lumen endotracheal tube and bronchial blocker in human cadavers.

BACKGROUND A novel double-lumen endotracheal tube, the Papworth BiVent tube, has been designed to allow the rapid passage of a blocker into either main bronchus, without fibreoptic endoscopic guidance. METHODS The feasibility of lung isolation and one-lung ventilation (OLV) in human cadavers is examined, along with displacement of the bronchus blocker during head and neck movement. RESULTS ...

متن کامل

[Selective lobar blockade with a Coopdech blocker combined with a double-lumen endotracheal tube for lung metastases resection by laser].

In recent years, laser resection of lung metastases has been established as the standard procedure worldwide. To avoid airway fire, it is necessary to collapse the surgical lung. The selective lobar bronchial blockade is a technique that allows one-lung ventilation while the operated lobe is collapsed in patients with previous pulmonary resection requiring subsequent resection or with limited p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 106 6  شماره 

صفحات  -

تاریخ انتشار 2011