Surface curvature estimation for automatic colonic polyp detection [5746-43]

نویسندگان

  • Adam Huang
  • Ronald M. Summers
  • Amy K. Hara
چکیده

Colonic polyps are growths on the inner wall of the colon. They appear like elliptical protrusions which can be detected by curvature-derived shape discriminators. For reasons of computation efficiency, much of the past work in computeraided diagnostic CT colonography adopted kernel-based convolution methods in curvature estimation. However, kernel methods can yield erroneous results at thin structures where the gradient diminishes. In this paper, we investigate three surface patch fitting methods: Cubic B-spline, paraboloid, and quadratic polynomials. This “patch” approach is based on the fact that a surface can be re-oriented such that it can be approximated by a bivariate function locally. These patch methods are evaluated by synthesized data with various orientations and sampling sizes. We find that the cubic spline method performs best regardless of large orientation variances. Cubic spline and quadratic polynomial methods perform equally well for large samples while the latter performs better for small ones. Based on the performance evaluation, we propose a new, two-stage curvature estimation method. The cubic spline fitting is performed first for its insensitivity to orientation. If the spline fitting errs by more than a preset value (indicating high surface tortuosity), a small data sample is fitted by a quadratic function. The evaluation is performed on 29 patients (58 data sets). With 88.7% sensitivity, the average number of false positives per data set is reduced by 44.5% from 33.5 (kernel method) to 18.6 (new method).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Principal Curvature-Based Colonic Polyp Detection

An automatic polyp detection framework is presented based on surface curvatures, and a new color coding scheme is used to highlight the detected polyps which enhances the visualization. An accurate estimate for the surface curvature together with three geometric features is used to detect the polyps. We place the detected polyps inside a polygonal dataset with exactly the same topology and geom...

متن کامل

Efficient Seeding and Defragmentation of Curvature Streamlines for Colonic Polyp Detection

Many computer aided diagnosis (CAD) schemes have been developed for colon cancer detection using Virtual Colonoscopy (VC). In earlier work, we developed an automatic polyp detection method integrating flow visualization techniques, that forms part of the CAD functionality of an existing Virtual Colonoscopy pipeline. Curvature streamlines were used to characterize polyp surface shape. Features d...

متن کامل

Candidate Determination for Computer Aided Detection of Colon Polyps

Given a segmented CT scan data of the colon represented as a triangle mesh, our water-plane algorithm will detect polyp candidates. The water-plane method comprises of pouring water into a polyp protrusion from the outside of the colon and in raising the “water-plane” until it cannot be incremented any further without causing water leakage. The method starts at a vertex and uses average normal ...

متن کامل

Surface Curvature Line Clustering for Polyp Detection in CT Colonography

Automatic polyp detection is a helpful addition to laborious visual inspection in CT colonography. Traditional detection methods are based on calculating image features at discrete positions on the colon wall. However large-scale surface shapes are not captured. This paper presents a novel approach to aggregate surface shape information for automatic polyp detection. The iso-surface of the colo...

متن کامل

Computer Aided Polyp Detection with Texture Analysis

We present a novel pipeline for computer-aided detection (CAD) of colonic polyps by integrating texture analysis with volume rendering and conformal colon flattening. Using our method, the 3D polyp automatic detection problem is converted into a 2D image analysis problem. The colon surface is first segmented and extracted from the CT data set of the abdomen, which is then mapped to a 2D rectang...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005