Thiocyanate in smokers interferes with the Nova magnesium ion-selective electrode.

نویسندگان

  • N N Rehak
  • S A Cecco
  • J E Niemela
  • R J Elin
چکیده

Thiocyanate found in serum ordinarily is the metabolite of cyanide that is inhaled with tobacco smoke and ingested with cyanogenic foods. We investigated the effect of the thiocyanate ion (SCN-) on the ionized magnesium (iMg) and ionized calcium (iCa) results determined with the AVL and Nova magnesium and calcium ion-selective electrodes (ISEs). We analyzed saline and pooled serum with added SCN-, and serum from apparently healthy nonsmokers (n = 20) and smokers (n = 20). The mean (and range) of the measured serum SCN- concentration was 0.019 (0.008-0.046) mmol/L for nonsmokers and 0.077 (0.020-0.138) mmol/L for smokers. Only the Nova iMg results decreased with increasing SCN- concentration, and the change was dependent on the baseline iMg concentration. In the absence of Mg, SCN- decreased the voltage response of the Nova Mg ISE to calcium ions. At apparently normal serum iMg and iCa concentrations, the interference by SCN- appeared to be equimolar (iMg = -1.04 x SCN- + 0.52). Thus, the serum SCN- commonly found in smokers causes a significant (P < 0.0001) decrease in the Nova iMg results.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Magnesium (II) by a Coated Graphite Electrode Based on Risperidone as an Ionophore

In this research, a coated graphite electrode was constructed for determination of Mg2+ in pharmaceutical supplements. The designed sensor demonstrates an ideal Nernstian slope (30.1 mV. Decade-1) over a wide concentration range (1×10-6- 1×10-1 Mol L-1). The selectivity of the sensor was evaluated over 16 different cations by matched potential method and no serious interference was observed fro...

متن کامل

Linearity and stability of the AVL and Nova magnesium and calcium ion-selective electrodes.

We studied the stability and linearity of the AVL and Nova Mg and Ca ion-selective electrodes and the relation between the ionized Ca and ionized Mg results reported by each analyzer. The response of the electrodes to different concentrations of Mg and Ca was determined for saline solutions, aqueous solutions, and serum samples. The electrodes from both manufacturers demonstrated acceptable sta...

متن کامل

Selective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.

A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...

متن کامل

Iodide selective membrane electrode based on copper (Π)-bis-Nphenilsalicyldenaminato complex

An iodide ion-selective PVC membrane sensor based on copper (Π)-bis-Nphenilsalicyldenaminatocomplex as a novel sensing material is successfully developed. Theelectrode showed a good selectivity for iodide ion with respect to common inorganic anions. Thesensor exhibited a good linear response with slope of _58.6 ± 0.4 mV per decade over theconcentration range of 5.0 × 10-6 to 1.0 × 10-1 mol L-1,...

متن کامل

Chromium(III) ion selective electrode based on 2H-1,4-benzothioazine-2,3(4H)dione dioxime as a neutral carrier

A poly(vinyl chloride) membrane based on a new a-dioxime derivative as membrane carrier was prepared andinvestigated as a Cr(III) selective electrode. The electrode exhibits a good potentiometric response for Cr(III)over a wide concentration range 1.0 x 10-6 to 1.0 x 10-1 M with a slope 19.5+0.5 mV/decade and low detectionlimit of 8.9 x 10-7 M. It has a fast response time < 15 s. The best perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 43 9  شماره 

صفحات  -

تاریخ انتشار 1997