Digitizing Tablet and Fahn–Tolosa–Marín Ratings of Archimedes Spirals have Comparable Minimum Detectable Change in Essential Tremor

نویسندگان

  • Rodger J Elble
  • Aaron Ellenbogen
چکیده

BACKGROUND Drawing Archimedes spirals is a popular and valid method of assessing action tremor in the upper limbs. We performed the first blinded comparison of Fahn-Tolosa-Marín (FTM) ratings and tablet measures of essential tremor to determine if a digitizing tablet is better than 0-4 ratings in detecting changes in essential tremor that exceed random variability in tremor amplitude. METHODS The large and small spirals of FTM were drawn with each hand on two consecutive days by 14 men and four women (age 60±8.7 years [mean±SD]) with mild to severe essential tremor. The drawings were simultaneously digitized with a digitizing tablet. Tremor in each digitized drawing was computed with spectral analysis in an independent laboratory, blinded to the clinical ratings. The mean peak-to-peak tremor displacement (cm) in the four spirals and mean FTM ratings were compared statistically. RESULTS Test-retest intraclass correlations (ICCs) (two-way random single measures, absolute agreement) were excellent for the FTM ratings (ICC 0.90, 95% CI 0.76-0.96) and tablet (ICC 0.97, 95% CI 0.91-0.99). Log10 tremor amplitude (T) and FTM were strongly correlated (logT=αFTM + β, α≈0.6, β≈-1.27, r=0.94). The minimum detectable change for the tablet and FTM were 51% and 67% of the initial assessment. DISCUSSION Digitizing tablets are much more precise than clinical ratings, but this advantage is mitigated by the natural variability in tremor. Nevertheless, the digitizing tablet is a robust method of quantifying tremor that can be used in lieu of or in combination with clinical ratings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using Portable Transducers to Measure Tremor Severity

BACKGROUND Portable motion transducers, suitable for measuring tremor, are now available at a reasonable cost. The use of these transducers requires knowledge of their limitations and data analysis. The purpose of this review is to provide a practical overview and example software for using portable motion transducers in the quantification of tremor. METHODS Medline was searched via PubMed.go...

متن کامل

Gamma knife thalamotomy for disabling tremor: a blinded evaluation.

BACKGROUND Gamma knife thalamotomy (GKT) has been used as a therapeutic option for patients with disabling tremor refractory to medications. Impressive improvement of tremor has been reported in the neurosurgical literature, but the reliability of such data has been questioned. OBJECTIVE To prospectively evaluate clinical outcomes after GKT for disabling tremor with blinded assessments. DES...

متن کامل

A computerized tablet system for evaluating treatment of essential tremor by magnetic resonance guided focused ultrasound

BACKGROUND Transcranial magnetic resonance guided focused ultrasound is an emerging technology under evaluation for treatment of essential tremor, a prevalent movement disorder. A qualitative evaluation is performed by a clinician periodically during the procedure to maximize treatment effects and minimize adverse effects. The present work demonstrates a magnetic resonance-compatible method to ...

متن کامل

Methods for Essential Tremor Assessment: Acoustic Tremor Monitoring (ATM) and Rhythmic Spirals (RS) Methods

There are several techniques of monitoring essential tremors, but there is not yet a standard method developed for the field. A quantitative way to track effects of medication and/or lifestyle treatment would be beneficial for future research in prevention or regression of essential tremors. The two methods evaluated are acoustic tremor monitoring (ATM) and rhythmic spirals (RS). The novel ATM ...

متن کامل

Validation of a new tool for automatic assessment of tremor frequency from video recordings.

We present a validation study for TremAn--a tool for automatic detection of tremor and measurement of its frequency from video recordings. To assess the validity of TremAn we designed a study consisting of tremor assessment from video, by accelerometry and by clinical evaluation using Fahn-Tolosa-Marin scale. 26 patients with essential tremor and 5 healthy volunteers underwent the examination i...