A tangential viewing, 10.59 microm CO(2) laser polarimeter for electron density measurements based on plasma induced Faraday rotation has been installed on DIII-D. The system uses colinear right- and left-hand circularly polarized beams with a difference frequency of 40 MHz to generate the necessary signal for heterodyne phase detection. The high-resolution phase information required to adequately resolve degree level polarization rotation is obtained using an all-digital "real-time" phase demodulation scheme based on modern digital signal processing techniques. Initial application of the system to DIII-D disruption mitigation experiments utilizing "massive gas jet" injection exhibits reliable operation and excellent agreement with CO(2) interferometer measurements; interestingly, the obtained Faraday rotation angles are in the range of those expected in ITER plasmas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Faraday-effect polarimeter-interferometer system for current density measurement on EAST.

A multichannel far-infrared laser-based POlarimeter-INTerferometer (POINT) system utilizing the three-wave technique is under development for current density and electron density profile measurements in the EAST tokamak. Novel molybdenum retro-reflectors are mounted in the inside wall for the double-pass optical arrangement. A Digital Phase Detector with 250 kHz bandwidth, which will provide re...

متن کامل

Faraday rotation measurements on compact helical system by using a phase sensitive heterodyne polarimeter

A phase sensitive heterodyne polarimeter was installed on compact helical system ~CHS!. An HCN laser ~337 mm! and Schottky barrier diodes are used for the radiation source and for detection, respectively. By using a phase sensitive heterodyne scheme, the Faraday rotation angle can be measured from the phase variations caused by the phase difference between the rightand left-handed waves in the ...

متن کامل

A Stark-tuned laser application for interferometry and polarimetry on the National Spherical Torus Experiment

Interferometer/polarimeter systems based on far infrared lasers have suffered from lack of frequency modulation techniques that can allow higher intermediate frequency ~IF! frequency for a fast time resolution together with stable operation including low frequency drift. This is mainly due to the intrinsic narrow gain profile of the lasers. It is known that the Stark effect can broaden the lase...

متن کامل

Program and Book of Abstracts

A double-path radially viewing multichannel far-infrared (FIR) polarimeter/interferometer system is under development for current density profile and electron density profile measurements for EAST tokamak. The system utilizes three 432 m CW formic acid FIR lasers pumped by three CO2 lasers. Three FIR lasers can generate high output power, more than 30 mW at each cavity. Two of them will be coun...

متن کامل

Pedestal magnetic field measurements using a motional Stark effect polarimeter.

Temperature-controlled, 0.15 nm interference filters were installed on an edge-viewing system of the motional Stark effect (MSE) polarimeter on the DIII-D tokamak. The upgraded system provides a factor of two reduction in the bandpass compared to the previous design, and linear control of the bandpass, which is unaltered by wavelength tuning. With the new system, there is a reduced dependence o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 79 10  شماره 

صفحات  -

تاریخ انتشار 2008