Ultra-Sensitive Potentiometric Measurements of Dilute Redox Molecule Solutions and Determination of Sensitivity Factors at Platinum Ultramicroelectrodes.
نویسندگان
چکیده
Open circuit potential (OCP) measurements can be very sensitive to small changes in the electrode environment and may allow detection of electron transfer events involving few, and maybe single, electrons. Factors affecting the overall sensitivity of OCP measurements were investigated to achieve the highest sensitivity. The OCP of platinum ultramicroelectrodes (UMEs) was determined in solutions that initially contained only supporting electrolyte where the OCP is a mixed potential governed by background faradaic processes. Then, increasing amounts of a redox couple at equimolar amounts of oxidized and reduced forms were added. In dilute solutions of the redox couple, the OCP deviates from the redox potential because of additional background half reactions occurring at the electrode. These dominate the OCP through their partial current contributions, shifting the OCP to a mixed potential region. The OCP at a platinum UME remains unchanged from the aqueous electrolyte solution mixed potential until ∼10-6 to 10-7 M concentrations of redox molecules are reached. At higher concentrations, the OCP moves toward the formal potential of the redox couple and eventually becomes poised at this value. By using a simple surface modification, the sensitivity to changing concentrations can be increased by almost 2 orders of magnitude. Numerical calculations with a Butler-Volmer formalism can estimate the contribution to the OCP mixed potential from background half reaction currents which are used to extract sensitivity factors from the change in potential with respect to current. The relative sensitivity to changing concentrations is shown to increase as the electrode size decreases.
منابع مشابه
Selective Potentiometric Sensor for Isoniazid Ultra-Trace Determination Based on Fe3O4 Nanoparticles Modified Carbon Paste Electrode (Fe3O4/CPE)
Significant effects of magnetic iron oxide (Fe3O4) nanoparticles on the potentiometric behavior of carbon paste electrode for bio determination of Isoniazid aromatic drug (INH) were studied. The electrochemical performance of modified Fe3O4/CPE was investigated. The constructed Fe3O4/CPE showed high precision, sensitivity ...
متن کاملUltra-Sensitive Optical Biosensor Based on Whispering Gallery Modes: The Effect of Buffer Solutions Refractive Index on Their Sensitivity and Performance
Background: Whispering gallery modes (WGM) biosensors are ultrasensitive systems that can measure amount of adsorbed layer onto the micro-cavity surface. They have many applications including protein, peptide growth, DNA and bacteria detection, molecular properties measurements and specific interaction and drug table recognitions due to their high sensitivity, compact size and label free sensin...
متن کاملStudy of Aptamer-Attached Juglone in Different pH Ranges and Ionic Concentrations of Buffers
Electrochemical aptamer-based sensors attract a lot of interest as useful methods because of their low cost, accuracy, sensitivity, and simplicity. An electro-active redox molecule comprises the main part of the electrochemical-based sensors. Ferrocene is one of the most popular redox molecule used in biosensor fabrication. But, instability of ferrocenium ion in strong nucleophilic reagents...
متن کاملResponse Surface Methodology in Spectrophotometric Determination of Formaldehyde Using Ch romotropic Acid
Formaldehyde in small quantities is commonly analyzed by spectrophotometric methods. One of the most-commonly used spectrophotometric techniques for this purpose is based on the reaction with chromotropic acid. Because of its simplicity, sensitivity, selectivity and its low cost, it is still widely used. Investigations for replacing the concentrated sulfuric acid with other acids or using more ...
متن کاملA NOVEL AND HIGHLY SENSITIVE CATALYTIC METHOD FOR THE DETERMINATION OF ULTRA TRACE AMOUNTS OF CERIUM WITH SPECTROPHOTOMETRIC DETECTION
Cerium (IV) has a catalytic effect on the very slow redox reaction between gallocyanine and bromate in acidic media. The reaction was monitored spectrophotometrically at 525 nm by a fixed time method of 4.0 rnin from initiation of the reaction. The decrease in absorbance at 525 nm is proportional to the Ce (IV) concentration in the range of 0.005-1.000 and 1.00-10.00 pg. ml-l. The limit of ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 89 18 شماره
صفحات -
تاریخ انتشار 2017