Right ventricular (RV) velocity measurements using high resolution spiral myocardial phase velocity mapping (PVM)
نویسندگان
چکیده
Background PVM is capable of accurately and reproducibly measuring myocardial velocities in the LV [1]. However, analyzing RV motion is more difficult because of the thinness of the free wall and its asymmetrical geometry. Currently, the most commonly used technique for assessing RV velocities and function is Tissue Doppler Imaging (TDI) where the high temporal resolution allows the detailed analysis of fine features of motion (small peaks in velocity during isovolumic contraction (IC) and isovolumic relaxation (IR) [2], for example). However TDI is restricted by inadequate acoustic windows and cannot comprehensively assess velocities over the entire RV. This study aims to establish that high resolution spiral PVM is capable of reproducibly measuring RV free wall velocities and that, consequently, it has a future role in assessing RV function.
منابع مشابه
High resolution spiral myocardial phase velocity mapping (PVM) of the entire cardiac cycle
Background Three-directional PVM is capable of measuring regional myocardial velocities. Current techniques use Cartesian k-space coverage, and navigator-gated high spatial and temporal resolution acquisitions are long [1,2]. In addition, they use prospective ECG-gating and analysis of the full cardiac cycle is not possible. The aim of this study is to develop a high temporal and spatial resolu...
متن کاملMyocardial velocity mapping for the right ventricle in pulmonary arterial hypertension using a novel image-based respiratory self-navigation from a golden-angle spiral acquisition
Background CMR is a recognized method of assessing global RV function in patients with pulmonary arterial hypertension (PAH). Unfortunately, assessment of regional myocardial motion with MRI remains challenging due to the thin RV wall. One solution may be tissue phase mapping (TPM) in which motion can be encoded at a higher spatial resolution. However, one problem is the need for respiratory na...
متن کاملReproducibility of peak and time to peak velocity measurements with a high resolution spiral phase velocity mapping (PVM) sequence
Background Myocardial PVM may be used to assess peak velocities and the times to those peaks (TTP) in order to characterise healthy and pathological regional heart motion [1]. However data on the reproducibility of the technique is limited. A previous breathhold (low resolution) study investigated reproducibility for peak radial and circumferential velocities [2]; however that of TTP measuremen...
متن کاملEfficient and reproducible high resolution spiral myocardial phase velocity mapping of the entire cardiac cycle
BACKGROUND Three-directional phase velocity mapping (PVM) is capable of measuring longitudinal, radial and circumferential regional myocardial velocities. Current techniques use Cartesian k-space coverage and navigator-gated high spatial and high temporal resolution acquisitions are long. In addition, prospective ECG-gating means that analysis of the full cardiac cycle is not possible. The aim ...
متن کاملApplication of through-time spiral GRAPPA to phase velocity mapping (PVM)
Background PVM is an established technique for measuring blood [1] and myocardial velocities [2]. However, long scan times can restrict its application. Peak-GRAPPA has been used to accelerate Cartesian PVM up to a factor of 6 (R = 6) without degrading peak velocity measurements [3], however use of efficient k-space trajectories could allow higher temporal resolution (TR) in similar scan time. ...