Peripheral hyperacuity: isoeccentric bisection is better than radial bisection.
نویسندگان
چکیده
Performance of three-dot bisection was determined as a function of orientation for a variety of feature separations and field meridians at eccentricities of 0-10 deg for two observers. The dot stimuli and separations were scaled in size to compensate for eccentricity. The precision of three-dot bisection was found to depend on the direction of test-feature offset. In the fovea, horizontal and vertical bisections were better than oblique bisections, while at eccentricities of 5-20 deg, isoeccentric (on a tangent to a circle of a given eccentricity) bisection was better than radial bisection. The direction of offset was more important than the orientation of the stimulus. Large separations showed a stronger effect than small separations. The anisotropy of bisection appears different from the meridional effect for resolution and is unlikely to be simply related to a local anisotropy of the cortical magnification factor.
منابع مشابه
Optimal spatial localization is limited by contrast sensitivity
Bisection is one of several spatial localization tasks that achieve hyperacuity performance levels. We find that optimal bisection thresholds, and hyperacuity tasks in general, are no better than might be expected from simple contrast detection and discrimination performance. The three-line bisection task can be described in terms of the test-pedestal paradigm where the test pattern is a horizo...
متن کاملPosition sense of the peripheral retina.
Position acuity was measured over a wide range of eccentricities, from 3 min to 10 deg in the horizontal meridian, by using both a three-dot bisection task and a three-dot vernier task. A foveal fixation dot appeared for 1 sec before an outer pair of test dots was flashed for 200 msec. Bisection and vernier tasks were used to measure position acuity in the radial and tangential directions, resp...
متن کاملPositional uncertainty in peripheral and amblyopic vision.
Three experiments were performed to examine positional acuity and the role of spatial sampling in central, peripheral and amblyopic vision. In the first experiment, 3-line bisection acuity was compared to grating acuity. In normal foveal vision bisection acuity represents a hyperacuity. In anisometropic amblyopes, bisection acuity is reduced in rough proportion to their grating acuity. In strab...
متن کاملPeripheral positional acuity: retinal and cortical constraints on 2-dot separation discrimination under photopic and scotopic conditions.
The precision of discriminating the separation of two dots was measured as a function of separation for eccentricities of 0-10 deg under photopic and scotopic conditions. At each eccentricity, the 2-dot separation discrimination thresholds showed a V-shaped dependence on separation. For separations less than approximately twice the resolution threshold, performance deteriorated from photopic to...
متن کاملPeripheral hyperacuity: three-dot bisection scales to a single factor from 0 to 10 degrees.
Performance of three-dot bisection was determined as a function of the feature separation at eccentricities of 0-10 deg along the inferior vertical field meridian by using dot stimuli scaled in size to compensate for eccentricity. For these briefly flashed dot stimuli, the entire function of three-dot bisection acuity against dot separation worsens away from the fovea with a single scaling fact...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Optical Society of America. A, Optics and image science
دوره 4 8 شماره
صفحات -
تاریخ انتشار 1987