Research Papers Involving the TSI DustTrak Aerosol Monitor - Application Note ITI-079

ثبت نشده
چکیده

Particulate air pollution, specifically the fine particle fraction (PM2.5), has been associated with increased cardiopulmonary morbidity and mortality in general population studies. Occupational exposure to fine particulate matter can exceed ambient levels by a large factor. Due to increased interest in the health effects of particulate matter, many particle sampling methods have been developed. In this study, two such measurement methods were used simultaneously and compared. PM2.5 was sampled using a filter-based gravimetric sampling method and a direct-reading instrument, the TSI Inc. Model 8520 DUSTTRAKTM aerosol monitor. Both sampling methods were used to determine the PM2.5 exposure in a group of boilermakers exposed to welding fumes and residual fuel oil ash. The geometric mean PM2.5 concentration was 0.30 mg/m (GSD 3.25) and 0.31 mg/m (GSD 2.90) from the DUSTTRAKTM monitor and gravimetric method, respectively. The Spearman rank correlation coefficient for the gravimetric and DUSTTRAKTM monitor PM2.5 concentrations was 0.68. Linear regression models indicated that loge DUSTTRAKTM monitor PM2.5 concentrations significantly predicted loge gravimetric PM2.5 concentrations (p < 0.01). The association between loge DUSTTRAKTM monitor and loge gravimetric PM2.5 concentrations was found to be modified by surrogate measures for seasonal variation and type of aerosol. PM2.5 measurements from the DUSTTRAKTM monitor are well correlated and highly predictive of measurements from the gravimetric sampling method for the aerosols in these work environments. However, results from this study suggest that aerosol particle characteristics may affect the relationship between the gravimetric and DUSTTRAKTM monitor PM2.5 measurements. Recalibration of the DUSTTRAKTM monitor for the specific aerosol, as recommended by the manufacturer, may be necessary to produce valid measures of airborne particulate matter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Research Papers Involving the TSI RespiCon Sampler - Application Note ITI-080

Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, a...

متن کامل

Characterisation of CS Aerosol used in Mask Test Facilities

CS aerosol (o-chlorobenzylidene malonitrile) is a low to moderate toxicity irritant used by Australian Defence Force for respiratory protection training. It is classified as a hazardous substance with an occupational exposure limit of 0.39 mg/m3 (STEL-C). Currently the ADF has no means of measuring the concentration of CS aerosol used within the Mask Test Facilities (MTF) during CBRN training. ...

متن کامل

Correction factor for continuous monitoring of wood smoke fine particulate matter.

The US Environmental Protection Agency (EPA) has designated a handful of instruments as Federal Reference or Federal Equivalency Methods (FRM and FEM, respectively) for the monitoring of fine particulate matter (PM2.5). More commonly used for indoor exposure assessment studies are optical scanning devices such as the DustTrak (TSI) due to the their portability and affordability. It is recommend...

متن کامل

Research Papers Involving the Tsi Respicontm Sampler

Six inhalable aerosol samplers were evaluated experimentally as area samplers using monodisperse solid particles with aerodynamic diameters ranging from 5 to 68 mm. Sampler performance and inside particle loss at two test wind speeds (0.55 and 1.1 m/sec) and three wind orientations (0, 90, and 180 degrees) were investigated. The six inhalable aerosol samplers tested were a RESPICONTM sampler, a...

متن کامل

An inexpensive dual-chamber particle monitor: laboratory characterization.

In developing countries, high levels of particle pollution from the use of coal and biomass fuels for household cooking and heating are a major cause of ill health and premature mortality. The cost and complexity of existing monitoring equipment, combined with the need to sample many locations, make routine quantification of household particle pollution levels difficult. Recent advances in tech...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009