Predictability of electron cone ratios with respect to linac make and model

نویسندگان

  • R. C. Tailor
  • D. S. Followill
  • N. Hernandez
  • G. S. Ibbott
  • W. F. Hanson
چکیده

In the past, the Radiological Physics Center (RPC) has developed standard sets of photon depth-dose and wedge-factor data, specific to the make, model, and wedge design of the linear accelerator (linac). In this paper, the RPC extends the same concept to electron-cone ratios. Since 1987, the RPC has measured and documented cone-ratio (CR) values during on-site dosimetry review visits to institutions participating in National Cancer Institute cooperative clinical trials. Data have been collected for approximately 500 electron beams from a wide spectrum of linac models. The analysis presented in this paper indicates that CR values are predictable to 2% to 3% (two standard deviations) for a given make and model of linac with a few exceptions. The analysis also revealed some other interesting systematics. For some models, such as the Varian Clinac 2500 and the Elekta/Philips SL18, SL20, and SL25, CR values were nearly identical for cone sizes 15 cm x 15 cm (or 14 cm x 14 cm) and 20 cm x 20 cm across the range of available energies. Certain models of the same make of linac, such as the Mevatron MD, KD, and 6700 series models or the Clinac 2100 and 2300 models, exhibited indistinguishable CRs. Irrespective of linac model, two consistent general trends were observed: namely, an increase in CR value with incident beam energy for cone sizes smaller than 10 cm x 10 cm and a decrease with energy for cone sizes larger than 10 cm x 10 cm. These data are valuable to the RPC as a quality assurance remote-monitoring tool to identify potential dosimetry errors. The physics community will also find the data useful in several ways: as a redundant check for clinical values in use, to validate the values measured during commissioning of new machines or to ensure consistency of values measured during annual quality assurance procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Benchmarking of Siemens Linac in Electron Modes: 8-14 MeV Electron Beams

Introduction: Radiation therapy using electron beams is a promising method due to its physical dose distribution. Monte Carlo (MC) code is the best and most accurate technique for forespeaking the distribution of dose in radiation treatment of patients.Materials and Methods: We report an MC simulation of a linac head and depth dose on central axis, along with profile calculations. The purpose o...

متن کامل

Efficiency of Information Coding in Various L/M Retinal Cone Ratios

Previous evidence has shown that the number of L and M cones in retina varies significantly between subjects. However, it is not clear how the variation of L/M ratio changes the behavioral performance of the subject. A model of transformation of data from retina to visual cortex for evaluation of various L/M cones ratios is presented. While L/M cone ratios close to 1 brings the best performance...

متن کامل

An assessment of the Photon Contamination due to Bremsstrahlung Radiation in the Electron Beams of a NEPTUN 10PC Linac using a Monte Carlo Method

Introduction: In clinical electron beams, most of bremsstrahlung radiation is produced by various linac head structures. This bremsstrahlung radiation dose is influenced by the geometry and construction of every component of the linac treatment head structures. Thus, it can be expected that the amount of the contaminated photon dose due to bremsstrahlung radiation varies among different linacs,...

متن کامل

Dental Materials Effect in Neutron Contamination: Electron Mode of a Linac

Background: Neutron contamination is produced in electron beams of linac when tooth or dental materials are located in the path of beam. Objective: This study aims to determine the neutron dose contamination from different dental restoration materials in electron mode of a linac. Material and Methods: In this experimental study, the neutron dose contamination was calculated in the p...

متن کامل

Soil Structure Interaction Effects on Hysteretic Energy Demand for Stiffness Degrading Systems Built on Flexible Soil Sites

This paper aims to study the influence of soil-structure interaction on plastic energy demand spectra directly derived from the energy-balance equations of soil-shallow-foundation structure with respect to an ensemble of far-field strong ground motions obtained from Pacific Earthquake Engineering Research (PEER) database and recorded on alluvium soil. The superstructure is modeled as a single-d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2003