Statistical Noise Analysis in SENSE Parallel MRI
نویسندگان
چکیده
A complete first and second order statistical characterization of noise in SENSE reconstructed data is proposed. SENSE acquisitions have usually been modeled as Rician distributed, since the data reconstruction takes place into the spatial domain, where Gaussian noise is assumed. However, this model just holds for the first order statistics and obviates other effects induced by coils correlations and the reconstruction interpolation. Those effects are properly taken into account in this study, in order to fully justify a final SENSE noise model. As a result, some interesting features of the reconstructed image arise: (1) There is a strong correlation between adjacent lines. (2) The resulting distribution is non-stationary and therefore the variance of noise will vary from point to point across the image. Closed equations for the calculation of the variance of noise and the correlation coefficient between lines are proposed. The proposed model is totally compatible with g-factor formulations.
منابع مشابه
Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI).
Parallel imaging methods become increasingly available on clinical MR scanners. To investigate the potential of sensitivity-encoded single-shot EPI (SENSE-EPI) for functional MRI, five imaging protocols at different SENSE reduction factors (R) and matrix sizes were compared with respect to their noise characteristics and their sensitivity toward functional activation in a motor task examination...
متن کاملA review on statistical noise models for Magnetic Resonance Imaging1
Many image processing applications within MRI are grounded on stochastic methods based on the prior knowledge on the statistics of noise. The ubiquitous Gaussian model provides a poor fitting for mediumlow SNRs, yielding to the use of Rician statistics: the noise in MRI has been traditionally modeled as a stationary process governed by a Rician distribution with constant noise power at each vox...
متن کاملFunctional MRI using regularized parallel imaging acquisition.
Parallel MRI techniques reconstruct full-FOV images from undersampled k-space data by using the uncorrelated information from RF array coil elements. One disadvantage of parallel MRI is that the image signal-to-noise ratio (SNR) is degraded because of the reduced data samples and the spatially correlated nature of multiple RF receivers. Regularization has been proposed to mitigate the SNR loss ...
متن کاملA Graphical Generalized Implementation of SENSE Reconstruction Using Matlab
Parallel acquisition of Magnetic Resonance Imaging (MRI) has the potential to significantly reduce the scan time. SENSE is one of the many techniques for the reconstruction of parallel MRI images. A generalized algorithm for SENSE reconstruction and theoretical background is presented. This algorithm can be used for SENSE reconstruction for any acceleration factor between 2 and 8, for any Phase...
متن کاملStatistical noise model in GRAPPA-reconstructed images
Noise in Parallel Imaging Parallel MRI (pMRI) techniques extended the applicability of multiple-coil systems by increasing the acquisition rate via subsampled acquisitions of the k-space data. Many reconstruction methods have been proposed in order to suppress the aliasing and underlying artifacts created by the subsampling. Dominant among these are SENSE and GRAPPA. One of the effects in accel...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- CoRR
دوره abs/1402.4067 شماره
صفحات -
تاریخ انتشار 2014