SU-E-I-40: Effective Dose Normalized to Dose Length Product for Pediatric and Adult Reference Phantoms in Computed Tomography Examinations.

نویسندگان

  • S Lamart
  • K Kim
  • W Bolch
  • C Lee
چکیده

PURPOSE To develop a set of conversion factors from dose length product (DLP) to effective dose (E) for pediatric and adult reference individuals undergoing computed tomography (CT) examinations. METHODS This study used 12 hybrid computational phantoms representing reference pediatric and adult individuals in compliance with the International Commission on Radiological Protection (ICRP) reference data. The phantoms were combined with a model of the Siemens Sensation 16 scanner, to compute organ doses from CT examinations using a radiation transport code, MCNPX2.7. Effective doses based on ICRP 60 and 103 tissue weighting factors were calculated. The DLP was derived from the scan length and Computed Tomography Dose Index (CTDI)vol. The resulting DLP-to-E conversion factors were analyzed. RESULTS The results consist in a set of DLP-to-E conversion factors for head, chest, abdomen, abdomen-pelvis, and chest-abdomen-pelvis CT examinations for newborn, 1-, 5-, 10-, 15-year-old and adult reference phantoms, for 80, 100 and 120 kVp and for ICRP 60 and 103 tissue weighting factors. The DLP-to-E factors decrease with smaller tube potential, with the greatest decrease for the head examinations for which values at 80 kVp are 20% smaller than at 120 kVp on average. The ICRP 103 weighting factors, compared to ICRP 60, Result in variations of DLP-to-E from 0.8 to 1.2-fold with a systematic increase for the chest, 1.14- fold on average, due to the increased breast weighting factor. The DLP-to-E factors for the body examinations are relatively similar to each other but 5 to 12-fold higher than for the head exam. The factors decrease with age until 15 years and then slightly increase for adult except for head. CONCLUSIONS An updated set of DLP-to-E conversion factors were established based on more realistic human phantoms and provide an improved accuracy to obtain effective dose from DLP for patients undergoing CT examinations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey

Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...

متن کامل

Assessment and evaluation of patient doses in adult common CT examinations towards establishing national diagnostic reference levels

Background: Patient radiation doses from computed tomography (CT) are increasing due to the number of CT examinations performed every day. The aim of this study was assess and evaluate patient radiation doses for adult’s common CT examinations to derive local diagnostic guidance levels for common CT examinations. Materials and Methods: Volume and weighted computed tomography dose index (C...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

Estimating the Radiation-Induced Cancer Risks in Pediatric Computed Tomography

Introduction One of the central questions in radiological protection is the magnitude of the risks from low doses of radiation, related to the justification and optimization of the diagnostic medical exposures. Therefore, the aim of this study was to estimate the cancer incidence and mortality risks in children of different ages, sizes, and ethnicities undergoing computed tomography examination...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 6Part4  شماره 

صفحات  -

تاریخ انتشار 2012