Star GK Bileaflet Mechanical Valve Prosthesis-Patient Mismatch After Mitral Valve Replacement: A Chinese Multicenter Clinical Study

نویسندگان

  • Hua Cao
  • Zhihuang Qiu
  • Liangwan Chen
  • Daozhong Chen
  • Qiang Chen
چکیده

BACKGROUND The aim of this study was to investigate the incidence and immediate and mid-term effects of heart valve prosthesis-patient mismatch (PPM) after mitral valve replacement using the GK bileaflet mechanical valve. MATERIAL AND METHODS A total of 493 cases of mechanical mitral valve replacement were performed in the departments of cardiac surgery in 7 hospitals from January 2000 to January 2008. The patients included 142 men and 351 women ages 21 to 67 (average age, 48.75). The patients were followed for 3 years after surgery. The effective orifice area index (EOAI), ≤1.2 cm2/m2, was detected during the follow-up period and was defined as PPM. The patients were assigned to either the PPM group or the non-PPM group. Finally, the preoperative, perioperative and postoperative indexes of the 2 groups of patients were compared. RESULTS A total of 157 patients had PPM 3 years after surgery. The incidence of PPM was 31.84%. Sixty-three patients in the PPM group received a 25-mm GK bileaflet valve (40.13%), 82 received a 27-mm valve (52.23%), and 12 (7.64%) received a 29-mm valve. There were significant differences in length of intensive care unit stay, duration of ventilator use, length of hospitalization, body surface area, EOAI, mean transmitral pressure gradient, and pulmonary artery pressure between the PPM and non-PPM group (P<0.05). There was a significant difference between preoperative and postoperative pulmonary artery pressures among non-PPM patients (P<0.05); however, there was no statistical difference in preoperative and postoperative pulmonary artery pressures among patients with PPM (P>0.05). CONCLUSIONS PPM after mitral valve replacement influences postoperative hemodynamics. Thus, larger-sized GK bileaflet mechanical valves are often used to reduce the risk of PPM.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Successful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis

Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...

متن کامل

Five-year follow-up after heart valve replacement with the CarboMedics bileaflet prosthesis.

BACKGROUND The CarboMedics valve is a relatively new, low-profile, bileaflet, mechanical prosthesis. The results of a prospective follow-up study after valve replacement with this prosthesis in a university hospital are presented. METHODS We implanted 640 CarboMedics prostheses in 583 patients in the aortic (n = 359), mitral (n = 167), or aortic and mitral positions (double valve replacement;...

متن کامل

Impact of patient-prosthesis mismatch and aortic valve design on coronary flow reserve after aortic valve replacement.

OBJECTIVES This prospective-randomized study investigated the effect of aortic valve design and patient-prosthesis mismatch (PPM) on coronary flow reserve (CFR) after mechanical or biological aortic valve replacement (AVR) in patients with aortic stenosis (AS). BACKGROUND Coronary flow reserve may be an important parameter of long-term survival after AVR in patients with AS. Reduced CFR may c...

متن کامل

Leaflet Escape in a New Bileaflet Mechanical Valve

Background—Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. Methods and Results—At the University of Padua, between November 2000 and ...

متن کامل

Replacement of an aortic Starr-Edwards ball valve prosthesis 28 years after implantation.

A 53-year-old woman who had undergone aortic valve replacement with a Starr-Edwards (S-E) valve (Model 1260) and open mitral commissurotomy 28 years previously was hospitalized with cardiac failure. Echocardiography showed mitral stenosis, mitral regurgitation, and a normally functioning S-E prosthesis. At reoperation, the mitral and aortic valves were replaced with St Jude bileaflet mechanical...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 21  شماره 

صفحات  -

تاریخ انتشار 2015