A correlator of time intervals between pulses.

نویسندگان

  • F F Hiltz
  • C T Pardoe
چکیده

I n the field of neurophysiology, analysis of the majority of neuronal data has been a tiresome task. Many questions and hypotheses posed by investigators in the field have remained unanswered and / or unverified because of inadequate analytical tools. For example, in the course of research at APL by F. F. Hiltz*, the need arose for an inexpensive means of ascertaining time relationships between spike discharges (pulses) in neurons. (Equipments that perform

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance of ultra-wideband correlator receiver using Gaussian monocycles

This paper investigates the performance of UltraWideband (UWB) correlator receivers for Gaussian monocycles under the condition of equal mean power and provides constructive reference to the selection of pulses. Several channel situations are examined including ideal single user AWGN channel, non-ideal synchronous, multipath fading and multiple access interference. Both numerical and analytical...

متن کامل

High-dynamic-range single-shot cross-correlator based on an optical pulse replicator.

The operation of a single-shot cross-correlator based on a pulse replicator is described. The correlator uses a discrete sequence of sampling pulses that are nonlinearly mixed with the pulse under test. The combination of a high reflector and partial reflector replicates an optical pulse by multiple internal reflections and generates a sequence of spatially displaced and temporally delayed samp...

متن کامل

Investigations of Microstructures and Magnetic Properties through Off-time between Pulses and Controlled Cu Content in Pulse Electrodeposited NiCu Nanowires

NiCu alloy nanowires arrays were embedded into the anodic aluminum oxide (AAO) template by ac-pulse electrodeposition. Different off-time were used in electrolyte with constant concentration of Ni and Cu and acidity of 3. The effect of deposition parameters on alloy contents was investigated by studying the microstructure and magnetic properties of as-deposited NiCu alloy nanowires. Atomic forc...

متن کامل

Comparison of the effect of quasitrapezoidal and rectangular pulses on bio- electrical activity, calcium spike properties and afterhyperpolarization potentials of Fl cells of Helix aspersa using intracellular recording

  While the effect of changes of stimulus waveform (quasitrapezoidal and rectangular current pulses) on nerve activation is clear, but there is no evidence on the effect of quasitrapezoidal pulses on ionic currents of cellular membrane. In the present study, the effect of depolarizing quasi-trapezoidal current pulses, in comparison with that of depolarizing rectangular current pulses, on firing...

متن کامل

Large tunable fractional delay of slow light pulse and its application to fast optical correlator.

The slow light device based on photonic crystal coupled waveguide was fabricated, and a tunable delay of 72 ps was obtained for 2-ps-wide slow light pulses by local heating, which corresponds to a tunable fractional delay of 36. This value was further enhanced to 110 by compressing the output pulses through self-phase modulation and dispersion compensation in external fibers. We applied this de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • IEEE transactions on bio-medical engineering

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 1965