What is the optimum minimum segment size used in step and shoot IMRT for prostate cancer?

نویسندگان

  • Yutaka Takahashi
  • Masahiko Koizumi
  • Iori Sumida
  • Toshiyuki Ogata
  • Yuichi Akino
  • Yasuo Yoshioka
  • Koji Konishi
  • Fumiaki Isohashi
  • Seiichi Ota
  • Takehiro Inoue
چکیده

Although the use of small segments in step and shoot IMRT provides better dose distribution, extremely small segments decrease treatment accuracy. The purpose of this study was to determine the optimum minimum segment size (MSS) in two-step optimization in prostate step and shoot IMRT with regard to both planning quality and dosimetric accuracy. The XiO treatment planning system and Oncor Impression Plus were used. Results showed that the difference in homogeneity index (HI), defined as the ratio of maximum to minimum doses for planning target volume, between the MSS 1.0 cm and 1.5 cm plans, and 2.0 cm plans, was 0.1%, and 9.6%, respectively. With regard to V107 of PTV, the volume receiving 107% of the prescribed dose of the PTV, the difference between MSS 1.0 cm and 1.5 cm was 2%. However, the value of the MSS 2.0 cm or greater plans was more than 2.5-fold that of the MSS 1.0 cm plan. With regard to maximum rectal dose, a significant difference was seen between the MSS 1.5 cm and 2.0 cm plans, whereas no significant difference was seen between the MSS 1.0 cm and 1.5 cm plans. Composite plan verification revealed a greater than 5% dose difference between planned and measured dose in many regions with the MSS 1.0 cm plan, but in only limited regions in the MSS 1.5 cm plan. Our data suggest that the MSS should be determined with regard to both planning quality and dosimetric accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot, Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Introduction: Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf c...

متن کامل

Step-and-Shoot versus Compensator-based IMRT: Calculation and Comparison of Integral Dose in Non-tumoral and Target Organs in Prostate Cancer

Introduction Intensity-Modulated Radiotherapy (IMRT) is becoming an increasingly routine treatment method. IMRT can be delivered by use of conventional Multileaf Collimators (MLCs) and/or physical compensators. One of the most important factors in selecting an appropriate IMRT technique is integral dose. Integral dose is equal to the mean energy deposited in the total irradiated volume of the p...

متن کامل

Assessment and Comparison of Homogeneity and Conformity Indexes in Step-and-Shoot and Compensator-Based Intensity Modulated Radiation Therapy (IMRT) and Three-Dimensional Conformal Radiation Therapy (3D CRT) in Prostate Cancer

Intensity modulated radiation therapy (IMRT) and three-dimensional conformal radiation therapy (3D CRT) are two treatment modalities in prostate cancer, which provide acceptable dose distribution in tumor region with sparing the surrounding normal tissues. IMRT is based on inverse planning optimization; in which, intensity of beams is modified by using multileaf collimators and also compensator...

متن کامل

A study of segment weight optimization with the CMS XiO step‐and‐shoot IMRT technique for prostate cancer

The aim of this study was to compare IMRT optimization in the CMS XiO radiotherapy treatment planning system, with and without segment weight optimization. Twenty-one prostate cancer patients were selected for this study. All patients were initially planned with step-and-shoot IMRT (S-IMRT). A new plan was then created for each patient by applying the segment weight optimization tool (SWO-IMRT)...

متن کامل

Optimization of prostate cancer radiotherapy using of a spacer gel, volumetric modulated arc therapy and a single biological organ at risk objective

Background: The aim was to evaluate the benefit of technical advances for treatment planning: introduction of a hydrogel spacer, VMAT (volumetric modulated arc therapy) and a single biological organ at risk objective for the rectum and bladder. Initial standard was a step-and-shoot IMRT (intensity modulated radiotherapy) without a spacer and conventional organ at risk objectives.  Material...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of radiation research

دوره 51 5  شماره 

صفحات  -

تاریخ انتشار 2010