Volumetric determinations with CAD/CAM in prosthetics and orthotics: errors of measurement.
نویسندگان
چکیده
During the next decade CAD/CAM technique will probably become routine in prosthetics and orthotics, not only as a complement to manual techniques, but also introducing new possibilities. However, even complex and sophisticated techniques have errors of measurement that must be considered. Such errors are of two principal kinds: systematic errors and random errors. In this study we have evaluated the Swedish CAPOD system with respect to volumetric determinations. We used two types of reference objects for volume determinations: cylinders and amputation residual limb models. Three different sizes were examined of each type of object. Volume measurements with CAPOD were compared with volumes obtained by water immersion or mathematical calculation (cylinders only). We found a constant, linear systematic error of +2.5%. Such an error can easily be corrected for. The random error, represented by the coefficient of variation, was 0.5%, which means that there is a theoretical possibility to detect volume changes exceeding 1%. We consider the precision sufficient for clinical practice in prosthetics and orthotics. Biological variations due to soft tissue deformation must be added on top of these errors. Such deformations were not evaluated in this study.
منابع مشابه
Accuracy and precision of volumetric determinations using two commercial CAD systems for prosthetics: a technical note.
The aim of this study was to evaluate the validity and reliability of volume determinations using the commercially available Seattle ShapeMaker CAD/CAM system for production of prosthetic sockets and to compare it with the commercially available CAPOD system. We used three types of reference objects for volumetric determinations: steel tubes, plaster of Paris casts, and residual limb models. Th...
متن کاملA trans-femoral brim adapter for CAD CAM measurements.
A computer aided design/computer aided manufacture (CAD CAM) brim measurement adapter was designed for use with a Berkeley casting stand. This measurement adapter accommodates all IPOS/CANFIT-PLUS transfemoral brim sizes and shapes, allows brim positioning, provides adequate stability, and provides a substantial cost saving by using existing, functional hardware as a base.
متن کاملA CAD analysis programme for prosthetics and orthotics.
A CAD (computer aided design) analysis software package (CADVIEW) was designed for use with prosthetic and orthotic CAD CAM (computer aided design/computer aided manufacture) systems. Using the Microsoft Windows 3.1 environment, CADVIEW provides a series of anatomical shape viewing and analysis tools. These tools include simultaneous display of multiple sockets and multiple views, two dimension...
متن کاملThe use of CAD/CAM technology in prosthetics and orthotics--current clinical models and a view to the future.
This report examines the current clinical uses of CAD/CAM in prosthetics and orthotics. We conducted interviews to contrast patterns of CAD/CAM use in different private practice settings, at two different teaching institutions, and within two large Prosthetic and Orthotic delivery systems. Investigation into these patterns of use has revealed several lessons. First, there currently exist severa...
متن کاملComparison of the Effect of Custom Insole With CAD-CAM and Conventional Insole on FAOS Questionnaire Subscales in Patients With Plantar Fasciitis
Objective: One of the significant causes of foot pain is plantar fasciitis. The use of medical insoles is a conventional treatment for this condition. The purpose of this study was to compare the effect of the customized insole with the CAD-CAM and conventional insole on pain, symptoms, daily activity, exercise and recreational activity, and quality of life in patients with PF. Materials & Met...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1995