Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured by Spectral Domain Optical Coherence Tomography and Visual Field Defects in Standard Automated White-on-White Perimetry versus Pulsar Perimetry

نویسندگان

  • Maged Alnawaiseh
  • Lisann Hömberg
  • Nicole Eter
  • Verena Prokosch
چکیده

Purpose To compare the structure-function relationships between retinal nerve fiber layer thickness (RNFLT) and visual field defects measured either by standard automated perimetry (SAP) or by Pulsar perimetry (PP). Materials and Methods 263 eyes of 143 patients were prospectively included. Depending on the RNFLT, patients were assigned to the glaucoma group (group A: RNFL score 3-6) or the control group (group B: RNFL score 0-2). Structure-function relationships between RNFLT and mean sensitivity (MS) measured by SAP and PP were analyzed. Results Throughout the entire group, the MS assessed by PP and SAP correlated significantly with RNFLT in all sectors. In the glaucoma group, there was no significant difference between the correlations RNFL-SAP and RNFL-PP, whereas a significant difference was found in the control group. Conclusions In the control group, the correlation between structure and function based on the PP data was significantly stronger than that based on SAP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correlation between peripapillary retinal nerve fiber layer thickness and fundus autofluorescence in primary open-angle glaucoma

PURPOSE To investigate the relationship between retinal nerve fiber layer (RNFL) thickness and retinal pigment epithelium alterations in patients with advanced glaucomatous visual field defects. METHODS A consecutive, prospective series of 82 study eyes with primary open-angle glaucoma and advanced glaucomatous visual field defects were included in this study. All study participants underwent...

متن کامل

Correlation between Retinal Nerve Fiber Layer Thickness by Optical Coherence Tomography and Perimetric Parameters in Optic Atrophy

PURPOSE To investigate the correlation between retinal nerve fiber layer (RNFL) thickness determined by optical coherence tomography (OCT) and visual field (VF) parameters in patients with optic atrophy. METHODS This study was performed on 35 eyes of 28 patients with optic atrophy. RNFL thickness was measured by OCT (Carl Zeiss, Jena, Germany) and automated perimetry was performed using the H...

متن کامل

Retinal nerve fiber layer thickness in glaucomatous and normal patients using spectral domain optical coherence tomography and standard automated perimetry-a comparative analysis

Glaucoma is characterized by a combination of structural changes in the retina and optic nerve head and functional perimetric damage. Examination and documentation of the retinal nerve fiber layer are essential for the diagnosis and monitoring of glaucoma. Spectral domain Optical coherence tomography (OCT) is a high resolution imaging device capable of obtaining reproducible retinal nerve fiber...

متن کامل

Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients

OBJECTIVE To evaluate the relationship between spectral-domain optical coherence tomography (OCT) and standard automated perimetry (SAP) in healthy and glaucoma individuals. METHODS The sample comprised 338 individuals divided into 2 groups according to intraocular pressure and visual field outcomes. All participants underwent a reliable SAP and imaging of the optic nerve head with the Cirrus...

متن کامل

Short wave–automated perimetry (SWAP) versus optical coherence tomography in early detection of glaucoma

OBJECTIVE To assess the role and diagnostic effectiveness of optical coherence tomography (OCT) and short wave-automated perimetry (SWAP) to distinguish between normal, glaucoma suspects, and surely diagnosed glaucomatous eye. BACKGROUND Changes in the optic disc and retinal nerve fiber layer (RNFL) often precede the appearance of visual field defect with standard automated perimetry. Unfortu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017