Duplicating a tandem and ovoids distribution with intensity‐modulated radiotherapy: a feasibility study

نویسندگان

  • Harish K. Malhotra
  • Jaiteerth S. Avadhani
  • Steven F. de Boer
  • Wainwright Jaggernauth
  • Michael R. Kuettel
  • Matthew B. Podgorsak
چکیده

Brachytherapy plays an important role in the definitive treatment of cervical cancers by radiotherapy. In the present study, we investigated whether sliding-window intensity-modulated radiation therapy (IMRT) can achieve a pear-shaped distribution with a similar sharp dose falloff identical to that of brachytherapy. The computed tomography scans of a tandem and ovoid patient were pushed to both a high dose rate (HDR) and an IMRT treatment planning system (TPS) after the rectum, bladder, and left and right femoral heads had been outlined, ensuring identical structures in both planning systems. A conventional plan (7 Gy in 5 fractions, defined as the average dose to the left and right point A) was generated for HDR treatment. The 150%, 125%, 100%, 75%, 50%, and 25% isodose curves were drawn on each slice and then transferred to the IMRT TPS. The 100% isodose envelope from the HDR plan was the target for IMRT planning. A 7-field IMRT plan using 6-MV X-ray beams was generated and compared with the HDR plan using isodose conformity to the target and 125% volume, dose-volume histograms, and integral dose. The resulting isodose distribution demonstrated good agreement between the HDR and IMRT plans in the 100% and 125% isodose range. The dose falloff in the HDR plan was much steeper than that in the IMRT plan, but it also had a substantially higher maximum dose. Integral dose for the target, rectum, and bladder were found to be 6.69 J, 1.07 J, and 1.02 J in the HDR plan; the respective values for IMRT were 3.47 J, 1.79 J, and 1.34 J. Our preliminary results indicate that the HDR dose distribution can be replicated using a standard sliding-window IMRT dose delivery technique for points lying closer to the three-dimensional isodose envelope surrounding point A. Differences in radiobiology and patient positioning between the two techniques merit further consideration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study

Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...

متن کامل

A Feasibility Study of IMRT of Lung Cancer Using Gafchromic EBT3 Film

Background: Intensity modulated radiation therapy (IMRT) is an advanced method for delivery of three dimensional therapies, which provides optimal dose distribution with giving multiple nonuniform fluency to the patient. The complex dose distribution of IMRT should be checked to ensure that the accurate dose is delivered. Today, film dosimetry is a powerful tool for radiotherapy treatment Quali...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

Dose Distribution Analysis of Rapid Arc and Intensity Modulated Radiotherapy Plan in Head and Neck Cancer

Introduction: Globally, intensity-modulated radiation therapy (IMRT) is considered as highly precise and accurate method of radiotherapy planning. This technique amplifies spatial dose distribution conformity by modulating the intensity of radiation beams in each sub-volume. Additionally, it can reduces the dose to surrounding critical organs and deliver the planned dose to targets with the nom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2007