Microporous polysaccharide hemosphere absorbable hemostat use in cardiothoracic surgical procedures

نویسندگان

  • Brian A Bruckner
  • Lance N Blau
  • Limael Rodriguez
  • Erik E Suarez
  • Uy Q Ngo
  • Michael J Reardon
  • Matthias Loebe
چکیده

BACKGROUND Topical hemostatic agents are used to reduce bleeding and transfusion need during cardiothoracic surgery. We report our experience with Arista® AH Absorbable Hemostatic Particles (Arista® AH), a novel plant-based microporous polysaccharide hemostatic powder. METHODS Data were retrospectively collected for patients (n = 240) that received cardiothoracic surgery at our institution from January 2009 to January 2013 with (n = 103) or without (n = 137) the use of Arista® AH. Endpoints included protamine to skin closure time (hemostasis time), cardiopulmonary bypass time, quantity of Arista® AH applied, intraoperative blood product usage, intraoperative blood loss, chest tube output 48 hours postoperatively, blood products required 48 hours postoperatively, length of stay in the intensive care unit, 30-day morbidity, and 30-day mortality. RESULTS 240 patients (176 M: 64 F) underwent 240 cardiothoracic procedures including heart transplantation (n = 53), cardiac assist devices (n = 113), coronary artery bypass grafts (n = 20), valve procedures (n = 19), lung transplantation (n = 17), aortic dissection (n = 8), and other (n = 10). Application of Arista® AH led to significant reduction in hemostasis time versus the untreated control group (Arista® AH: 93.4 ± 41 min. vs. CONTROL 107.6 ± 56 min., p = 0.02). Postoperative chest tube output in the first 48 hours was also significantly reduced (Arista® AH: 1594 ± 949 mL vs. CONTROL 2112 ± 1437 mL, p < 0.001), as well as transfusion of packed red blood cells (Arista® AH: 2.4 ± 2.5 units vs. CONTROL 4.0 ± 5.1 units, p < 0.001). There was no significant difference in 30-day mortality or postoperative complications. CONCLUSION Use of Arista® AH in complex cardiothoracic surgery resulted in a significant reduction in hemostasis time, postoperative chest tube output, and need for postoperative blood transfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of a plant-based polysaccharide hemostat for the treatment of sternal bleeding after median sternotomy

BACKGROUND In cardiac surgery profuse or persistent sternal bleeding after sternotomy is routinely controlled with bone wax. However, bone wax should be avoided, especially in high-risk patients for nonunion of the sternum and infections. Purpose of this study was to evaluate an alternative technique to control bleeding after medium sternotomy using a plant based absorbable polysaccharide hemos...

متن کامل

Health and economic outcomes associated with uncontrolled surgical bleeding: a retrospective analysis of the Premier Perspectives Database

BACKGROUND Bleeding remains a common occurrence in surgery. Data describing the burden of difficult-to-control bleeding and topical absorbable hemostat use are sparse. This study was conducted to estimate the clinical and economic impact that remains associated with uncontrolled surgical bleeding, even when hemostats are used during surgery. METHODS This US retrospective analysis used the Pre...

متن کامل

Safety and efficacy of microporous polysaccharide hemospheres in neurosurgery.

BACKGROUND Effective hemostasis is mandatory for brain tumor surgery. Microporous polysaccharide hemosphere (MPH) powder, a white powder compounded from potato starch, was recently introduced for surgical and emergency application. OBJECTIVE To evaluate the safety and efficacy of MPHs in brain tumor surgery. METHODS Thirty-three patients (mean age, 58 years; range, 22-84 years) underwent mi...

متن کامل

An in vivo comparison of the efficacy of hemostatic powders, using two porcine bleeding models

Background Usage of topical hemostatic agents in surgery is increasing, including use during minimally invasive procedures, and even for surgeries that have a low risk of bleeding complications. A novel product, Surgicel® Powder - Absorbable Hemostatic Powder (SP), made from oxidized regenerated cellulose (ORC) fabric, has been developed for adjunctive use in surgical procedures to assist in co...

متن کامل

The effects of sheet-type absorbable topical collagen hemostat used to prevent pulmonary fistula after lung surgery.

BACKGROUND Numerous reports have been published on the application of fibrin glues, biological adhesives used as sealants for air leaks after pulmonary resection; however, the use of blood products has been questioned from both safety and economic perspectives. Therefore we were prompted to attempt the use of Integran (method C), a sheet-type absorbable topical collagen hemostat that is neither...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014