Normal-phase separation effects with lipids on a silver Ion high- performance liquid chromatography column
نویسنده
چکیده
The separation of saturated fatty acids (as the methyl esters and as triacylglycerols) of differing chain lengths by silver ion chromatography (ChromSpher Lipids: containing silver ions: Chrompack, Middelburg, Netherlands) was studied, The retention characteristics (isocratic solvent system of acetonitrile in hexane) of saturated fatty acid methyl esters and homogeneous, saturated triacylglycerols were found to be inversely related to the number of carbon atoms in the fatty acid(s), Thus methyl stearate eluted first and methyl acetate eluted last: for triacylglycerols, tripalmitoylglycerol eluted first while triacetin was strongly retained (II min vs, 70 min), \Vhile mixtures of fatty acid methyl esters and of triacylglycerols could be separated, resolution was found to improve at higher concentrations of acetonitrile, a characteristic of normal-phase separations, In the absence of carbon-carbon double or triple bonds, the effects of the more polar silanol groups of the column packing tended to override the silver ion contributions (interaction of silver ions with the unpaired electrons of the carbonyl oxygens), resulting in separations similar to those observed in silica thin layer and normal-phase high-performance liquid chromatography, Ke.vwords: Silver ion liquid chromatography: Lipid: Fatty acid methyl ester: Triacylglycerol
منابع مشابه
Regioisomeric characterization of triacylglycerols using silver-ion HPLC/MS and randomization synthesis of standards.
Silver-ion normal-phase high-performance liquid chromatography (HPLC) provides a superior separation selectivity for lipids differing in the number and position of double bonds in fatty acid chains including the resolution of triacylglycerol (TG) regioisomers under optimized conditions. Our silver-ion HPLC method is based on the coupling of three columns in the total length of 75 cm and a new m...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملSeparation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column
The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...
متن کاملDetermination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کامل