Comparison of Two Ambient Beta Gauge PM10 Samplers.

نویسندگان

  • Chuen JinnTsai
  • Yu-Hsiang Cheng
چکیده

This paper reports on the performance of the Kimoto 180 sampler and the Wedding ambient PM10 beta gauge sampler. Monodisperse ammonium fluorescein test particles were generated in the laboratory and used to determine the penetration curve of the Kimoto 180 cyclonic inlet. It was found that the actual DpaSOof the Kimoto 180 inlet, 3.5 (xm, is much lower than the designated standard value, 10 um. In the field test, the two beta gauge samplers were collocated with an Andersen SA1200 high-volume sampler to compare their measured daily average PM10 concentrations. The low Dpa50 of the Kimoto 180 inlet serves to explain why its daily average PM10 concentrations were much lower than the actual PM10 concentrations found in the field study. In addition, the PM10 concentrations of the Kimoto 180 beta gauge sampler were found to be seriously affected by the water vapor content of the ambient air. In contrast, the daily average PM10 concentrations of the Wedding beta gauge sampler were found to be more accurate, and influences by ambient conditions were insignificant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characteristics: Ambient Pm10 Samplers

The National Ambient Air Quality Standards (NAAQS) for PM in terms of PM10 are ambient air concentration limits set by the EPA that should not be exceeded. Further, some state air pollution regulatory agencies (SAPRAs) utilize the NAAQS to regulate criteria pollutants emitted by industries by applying the NAAQS as property-line concentration limits. Prior to and since the inclusion of the PM10 ...

متن کامل

Comparison of Tests for Equivalence of Methods for Measuring PM10 Dust in Ambient Air

Our paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on ‘on-site’ measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standar...

متن کامل

The Design and Evaluation of a Low-volume Total Suspended Particulate Sampler

The regulation of particulate matter (PM) emitted by agricultural sources (cotton gins, feed mills, concentrated animal feeding operations (CAFOs) is based upon downwind concentrations of particulate matter less than 10 and 2.5 micrometers (μm) (PM10 and PM2.5) aerodynamic equivalent diameter (AED). Both PM10 and PM2.5 samplers operate by pre-separating PM larger than the size of interest (10 a...

متن کامل

Agricultural Particulate Matter Emissions: Preliminary Study

The Federal Reference Method (FRM) ambient PM10 sampler does not always measure the true PM10 concentration. There are inherent sampling errors associated with the PM10 samplers due to the interaction of particle size distribution (PSD) and sampler performance characteristics. These sampling errors, which are the relative differences between theoretical estimation of the sampler concentration a...

متن کامل

محتوای یونی و منابع انتشار احتمالی ذرات معلق هوای شهر تبریز در سال 93-92

Background and Objective: The present study was carried out to determine the amount and ionic characterization of TSP and PM10 aimed at identifying  the potential emission sources of particulates in the ambient air of Tabriz. Materials and Methods: TSP and PM10 samples were collected by two high volume samplers during September 2013 to August 2014. Water-soluble ions in particulate matter we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Air & Waste Management Association

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 1996