Treatment of eccentric fixation by the use of a red filter.
نویسنده
چکیده
THE treatment of amblyopia and eccentric fixation is said to be associated with special problems. In some centres pleoptics have been used, but the need for trained staff and special equipment can pose difficult problems. The harmful effects of conventional occlusion of the fixing eye have been stressed by Arruga (1962). Recently, Brinker and Katz (1963) have drawn attention to the fact that, as the fovea contains only cones, a red filter placed before the eye with non-central fixation while the dominant eye is occluded, may have the effect of inducing central'fixation by preferential stimulation of the fovea. This is because under red illumination only the photopic mechanism is active so that the cones of the fovea should be preferentially stimulated. However, Scully (1961) and von Noorden (1965) have pointed out that in many cases of eccentric fixation occlusion of the dominant eye does in fact lead to central fixation in the affected eye. In the present study, occlusion of the conventional type was compared with occlusion using the red filter in patients with eccentric fixation. Because the dangers of conventional occlusion have been so often stressed in such cases, it was decided that all patients should be given one month's inverse occlusion to the eccentric eye, before starting occlusion of the dominant eye, regardless of whether red filter treatment was subsequently used or not.
منابع مشابه
Trial with red filter in the treatment of eccentric fixation.
FOLLOWING the preliminary reports of Brinker and Katz (1963) and Binder, Engel, Ede, and Loon (1963) on the possible use of a red filter in the management of eccentric fixation, we tried this method of treatment in a series of eighteen cases, ten of which completed the investigation. Six of these were cases of eccentric fixation of the paramacular type, two of the parafoveal type, and two were ...
متن کاملRed filter treatment in eccentric fixation.
RED filter treatment was devised by Brinker and Katz (1963) to overcome some of the disadvantages inherent in conventional pleoptic methods-the necessity for regular attendance at hospital, lengthy sessions with the ophthalmologist, expensive equipment, and the difficulty of obtaining full co-operation and attention from the younger patients. The principle of the red filter is related to the fa...
متن کاملOphthalmoscopic attachment for the diagnosis of eccentric fixation.
THERE iS much need for earlier and more careful examination of patients, particularly children, who present with amblyopia in a squinting eye, with a view to the detection of eccentric fixation. It is true that in many cases considerable improvement of visual acuity may occur as a result of occlusion of the non-squinting eye, but there are others, mainly those with eccentric fixation, in which ...
متن کاملComparison of conventional, non-conventional (inverse), and red-filter occlusion
Occlusion of the sound eye (conventional occlusion) introduced by Buffon (I 743) was the only treatment for amblyopia until Bangerter (I953) introduced occlusion of the amblyopic eye (non-conventional or inverse occlusion) combined with pleoptic treatment in cases of amblyopia with eccentric fixation. Mackensen, Kroner, and Postic (I965), von Noorden (I965), Posti6 (I966), Borgmann and Dielefel...
متن کاملTreatment of Open Tibial Fractures: Convert-ing or Continuing External Fixation?
Background: The treatment of open tibial fractures is still an orthopaedic challenge and full of complications. In many cases the use of external fixator that has been known as a non-union machine is obligatory with a high incidence of pin track infection and other complications. The aim of this study was to compare the use of external fixation as a definite method for treatment of open tibial ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 52 12 شماره
صفحات -
تاریخ انتشار 1968