Comprehensive approach to coregistration of autoradiography and microscopy images acquired from a set of sequential tissue sections.

نویسندگان

  • Marian Axente
  • Jun He
  • Christopher P Bass
  • Jerry I Hirsch
  • Gobalakrishnan Sundaresan
  • Jamal Zweit
  • Andrei Pugachev
چکیده

UNLABELLED Histopathologic validation of a PET tracer requires assessment of colocalization of the tracer with its intended biologic target. Using thin tissue section autoradiography, it is possible to visualize the spatial distribution of the PET tracer uptake and compare it with the distribution of the intended biologic target (as visualized with immunohistochemistry). The purpose of this study was to develop and evaluate an objective methodology for deformable coregistration of autoradiography and microscopy images acquired from a set of sequential tissue sections. METHODS Tumor-bearing animals were injected with 3'-deoxy-3'-(18)F-fluorothymidine ((18)F-FLT), (14)C-FDG, and other markers of tumor microenvironment including Hoechst 33342 (blood-flow surrogate). After sacrifice, tumors were excised, frozen, and sectioned. Multiple stacks of sequential 8 μm sections were collected from each tumor. From each stack, the middle (reference) sections were used to obtain images of (18)F-FLT and (14)C-FDG uptake distributions using dual-tracer autoradiography. Sections adjacent to the reference were used to acquire all histopathologic data (e.g., images of cell proliferation, hematoxylin and eosin). Hoechst images were acquired from all sections. To correct for deformations and misalignments induced by tissue processing and image acquisition, the Hoechst image of each nonreference section was deformably registered to the reference Hoechst image. This transformation was then applied to all images acquired from the same tissue section. In this way, all microscopy images were registered to the reference Hoechst image. The Hoechst-to-autoradiography image registration was done using rigid point-set registration based on external markers visible in both images. RESULTS The mean error of Hoechst to (18)F-FLT autoradiography registration (both images acquired from the same section) was 30.8 ± 20.1 μm. The error of Hoechst-based deformable registration of histopathologic images (acquired from sequential tissue sections) was 23.1 ± 17.9 μm. Total error of registration of autoradiography images to the histopathologic images acquired from adjacent sections was evaluated at 44.9 μm. This coregistration precision supersedes current rigid registration methods with reported errors of 100-200 μm. CONCLUSION Deformable registration of autoradiography and histopathology images acquired from sequential sections is feasible and accurate when performed using corresponding Hoechst images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

A Statistical Method for Sequential Images – Based Process Monitoring

Today, with the growth of technology, monitoring processes by the use of video and satellite sensors have been more expanded, due to their rich and valuable information. Recently, some researchers have used sequential images for image defect detection because a single image is not sufficient for process monitoring. In this paper, by adding the time dimension to the image-based process monitorin...

متن کامل

مرزبندی کانی‌ها در تصویر مقاطع سنگ‌شناسی با استفاده از نرم‌افزار ArcGIS

In this paper, a new method for mineral boundary detection is proposed using a model prepared in ArcGIS ModelBuilder tool. Required data for this method are gray scale images taken from petrographic thin sections. The images are captured in 19 numbers through 90° polarizers and lambda plate rotation with 5° intervals while the microscope table is fixed. Mineral boundaries are detected using the...

متن کامل

Standard edge detection algorithms versus conventional auto-contouring used for a three-dimensional rigid CT-CT matching

Background: To reduce uncertainties of patient positioning, the Computerized Tomography (CT) images acquired at the treatment planning time can be compared with those images obtained during radiation dose delivery. This can be followed during dose delivery procedure as Image Guided radiotherapy (IGRT) to verify the prescribed radiation dose delivery to the target as well as to monitor ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 52 10  شماره 

صفحات  -

تاریخ انتشار 2011