Technique for a composite femoral intramedullary plug in cemented hip arthroplasty.
نویسندگان
چکیده
A brief technique to place a cement plug on top of a polyethylene is presented. This technique has helped the authors obtain better cement mantles when they are plugging the canal in total hip replacement.
منابع مشابه
Cemented Charnley revision arthroplasty for severe femoral osteolysis.
We reviewed prospectively cemented stem revision in 106 patients with severe femoral endosteal bone lysis without infection. Bone grafts were not used in any of the patients. The minimum follow-up was three years (mean 6 years 4 months). At the last review 76.4% of the patients were free of pain and 17.9% had only mild or occasional discomfort; radiographs showed well-fixed stable stems in 101 ...
متن کاملPrimary total hip arthroplasty with a retained intramedullary femoral nail.
Retained intramedullary femoral nails can pose a problem for the implantation of the femoral component during total hip arthoplasty (THA) and they must often be removed. A patient with a retained Küntscher femoral nail implanted 47 years previously presented in our outpatient clinic for a THA. Since removal of the nail was impossible without severe damage to the femur, we chose to perform an ex...
متن کاملHip Arthroplasty and its Revision in a Child: Case Report and Literature Review
Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...
متن کاملOutcomes of Charnley total hip arthroplasty using improved cementing with so-called second- and third-generation techniques
BACKGROUND Techniques of cemented total hip arthroplasty have developed over time. We present the outcomes of Charnley total hip arthroplasty performed using improved second- and third-generation cementing techniques. METHODS We reviewed the radiologic results of 91 Charnley total hip arthroplasties performed using second- and third-generation cementing techniques. Second-generation technique...
متن کاملA comparison of distal canal restrictors in primary cemented femoral hip arthroplasty.
A retrospective study evaluated 75 total hip arthroplasties performed over a 4-year period using 4 different cement restrictors. A harvested bone restrictor, polyethylene restrictor (Smith & Nephew, Richards Inc, Memphis, Tenn), Biostop G (Depuy Orthopaedics, Warsaw, Ind), and polymethylmethacrylate (PMMA) (Wright Medical Technology, Arlington, Tex) were compared for the percentage of failures,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of arthroplasty
دوره 14 3 شماره
صفحات -
تاریخ انتشار 1999