Photographic magnification of 35-mm cineangiographic frames utilizing subtraction film.

نویسندگان

  • A Embi
  • M Soto
  • B Befeler
چکیده

Most cardiovascular laboratories utilizing 35-mm cineradiographic techniques have the difEculty of not being able to project angiographic films to large audiences. One commercially available cineradiographic projector (Tagarno 35) provides relatively small images projected onto its own screen. When the screen is removed and the film is projected onto larger screens, a great deal of distortion takes place. Other projectors available to project these films onto large screens are not generally available and are expensive. Similarly, in the operating room, it is desirable to have a still image of the anatomy in order to better accomplish the surgical aims. This is particularly crucial when coronary bypass surgery is performed and the locations of the lesions and their severity dictate the location for the implantation of grafts. Otherwise, the surgeons have to carry the angiographic images in their memory, and this may lead to errors. When angiographic images are recorded on cut film or 105-mm photospots, they can usually be reviewed on standard x-ray viewing boxes. They have the ideal size for lectures and the operating room when viewed on standard viewing boxes. Not all laboratories utilize cut film or 105-mm photospots for a number of reasons which are beyond the scope of this communication. We have recently developed a simple and inexpensive method to transfer cineangiographic images onto highcontrast subtraction film with reversal of black and white (Dupont 14 x 14-inch subtraction film). These images can then be placed on a viewing box and reviewed when necessary, including during open-heart surgery in the operating room. This report presents the details of this technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereoscopic magnification in spinal angiography.

This technique combines the advantages of magnification and stereoscopic angiography. A heavy-duty x-ray tube oscillating between two positions (25 mm apart) allows serial spinal angiograms to be produced in stereo magnification (factor 2.0) using the 0.2 mm, 12 kW focal spot. The x-ray tube can be rapidly changed for normal serial angiography with a 0.6 mm, 50 kW focus. The technique is easy t...

متن کامل

Digital subtraction cerebral angiography by intraarterial injection: comparison with conventional angiography.

For 4 months, a prototype digital subtraction system was used to obtain images of the cerebral vasculature after intraarterial contrast injections. In 12 instances, the intraarterial injections were recorded with both a digital subtraction unit and conventional direct magnification film-screen system. The digital subtraction and conventional film subtraction images were compared and graded for ...

متن کامل

Assessing the capabilities of a 4kx4k CCD camera for electron cryo-microscopy at 300kV.

CCD cameras have numerous advantages over photographic film for detecting electrons; however the point spread function of these cameras has not been sufficient for single particle data collection to subnanometer resolution with 300kV microscopes. We have adopted spectral signal to noise ratio (SNR) as a parameter for assessing detector quality for single particle imaging. The robustness of this...

متن کامل

A comparison between the use of a high-resolution CCD camera and 35 mm film for obtaining coloured micrographs.

In light microscopy, colour CCD cameras are now capable of generating image data sets that contain more information than can be captured with slow 35 mm colour reversal film. The resolution of colour CCD cameras with a high density of sensor elements (> or = 3300 x 2200 per channel of colour) is equivalent to that of slow 35 mm colour film over typical fields of view for objectives with a wide ...

متن کامل

A 35mm 13.89 Million Pixel CMOS Active Pixel Image Sensor

This paper discusses a 13.89 million pixels CMOS image sensor for digital SLR cameras. The pitch of the 3transistor active pixel is 8 microns. The sensor has a full well charge of 117K electrons and 33 electrons temporal noise, and a dynamic range of 71 dB. The fixed pattern noise is 0.14% RMS, obtained by an on-chip correction circuit. Color filters have been optimized for best photographic pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chest

دوره 69 5  شماره 

صفحات  -

تاریخ انتشار 1976