Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS).
نویسندگان
چکیده
The analysis of explosives with ion mobility spectrometry (IMS) directly from aqueous solutions was shown for the first time using an electrospray ionization technique. The IMS was operated in the negative mode at 250 degrees C and coupled with a quadrupole mass spectrometer to identify the observed IMS peaks. The IMS response characteristics of trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DNT), 2-amino-4,6-dinitrotoluene (2-ADNT), 4-nitrotoluene (4-NT), trinitrobenzene (TNB), cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), cyclo-tetramethylene-tetranitramine (HMX), dinitro-ethyleneglycol (EGDN) and nitroglycerine (NG) were investigated. Several breakdown products, predominantly NO(2)(-) and NO(3)(-), were observed in the low-mass region. Nevertheless, all compounds with the exception of NG produced at least one ion related to the intact molecule and could therefore be selectively detected. For RDX and HMX the [M+Cl(-)](-) cluster ion was the main peak and the signal intensities could be greatly enhanced by the addition of small amounts of sodium chloride to the sprayed solutions. The reduced mobility constants (K(0)) were in good agreement with literature data obtained from experiments where the explosives were introduced into the IMS from the vapor phase. The detection limits were in the range of 15-190 microg l(-1) and all calibration curves showed good linearity. A mixture of TNT, RDX and HMX was used to demonstrate the high separation potential of the IMS system. Baseline separation of the three compounds was attained within a total analysis time of 6.4 s.
منابع مشابه
Secondary electrospray ionization ion mobility spectrometry/mass spectrometry of illicit drugs.
A secondary electrospray ionization (SESI) method was developed as a nonradioactive ionization source for ion mobility spectrometry (IMS). This SESI method relied on the gas-phase interaction between charged particles created by electrospray ionization (ESI) and neutral gaseous sample molecules. Mass spectrometry (MS) was used as the detection method after ion mobility separation for ion identi...
متن کاملCharacterizing electrospray ionization using atmospheric pressure ion mobility spectrometry.
Reduced flow rate electrospray ionization has been proven to provide improved sensitivity, less background noise, and improved limits of detections for ESI-MS analysis. Miniaturizing the ESI source from conventional electrospray to microelectrospray and further down to nanoelectrospray has resulted in higher and higher sensitivity; however, when effects of flow rate were investigated for atmosp...
متن کاملElectrospray Ionization-Ion Mobility Spectrometry (ESI-IMS) for Rapid On-site Cleaning Validation (CV) in Pharmaceutical Manufacturing Abstract
A novel high resolution ion mobility spectrometer (HRIMS) equipped with an electrospray ionization (ESI) source was used to analyze the active pharmaceutical ingredients (APIs) that comprise many of the top selling drugs for use in cleaning validation (CV) of pharmaceutical manufacturing equipment. The ESI-HRIMS system allowed rapid analysis of pharmaceutical samples that were difficult to dete...
متن کاملEvaluation of micro-electrospray ionization with ion mobility spectrometry/mass spectrometry
In recent years, the resolving power of ion mobility instruments has been increased significantly, enabling ion mobility spectrometry (IMS) to be utilized as an analytical separation technique for complex mixtures. In theory, decreasing the drift tube temperature results in increased resolution due to decreased ion diffusion. However, the heat requirements for complete ion desolvation with elec...
متن کاملEvaluation of capillary liquid chromatography-electrospray ionization ion mobility spectrometry with mass spectrometry detection.
Due to the proteomics revolution, multi-dimensional separation and detection instruments are required to evaluate many peptides and proteins in single samples. In this study, electrospray ionization (ESI) ion mobility spectrometry (IMS) was evaluated as an additional separation after HPLC separations. Common HPLC mobile phase compositions (solvents, acid modifiers, and buffers) were assessed fo...