Numerical analysis of a dental implant system preloaded with a washer.

نویسندگان

  • A Versluis
  • T W Korioth
  • A C Cardoso
چکیده

Gold screw loosening is a problem that frequently affects dental implants. The application of a preload has been the main means of preventing loosening. However, this measure has not been able to eliminate its occurrence. In this study the effect of a washer in a Brånemark-type implant on the loosening conditions of the retaining screw was investigated using a finite element simulation. The simulation indicated that a washer may significantly increase the tolerance of a screw against loosening. This is accomplished by increasing the tolerance of the implant against deformation. The addition of a customized washer to a dental implant system may offer a very simple and inexpensive solution for the persistent problem of screw loosening.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The accuracy of various torque wrenches used in dental implant systems

Introduction: The purpose of this study was to compare the accuracy of the torque wrenches used in different dental implant systems. Methods: We evaluated 42 torque wrenches used in different dental clinics in Mashhad, Iran, using a digital torque meter (Mark 10). High (25, 30 and 35 N·cm) and low (15 N·cm) levels of torque were examined. Ten tests were performed on each wrench, and the mean va...

متن کامل

Influence of Occlusal Forces on Stress Distribution on Preloaded Dental Implant Abutment Screws: A Finite Element Analysis Study

Purpose: The aim of the study is to determine stress distribution on preloaded implant-abutment screws in three different implant systems under simulated occlusal loads. Materials and methods: Three abutments to implant internal hex joint systems were simulated by using the 3-dimensional finite element analysis; (1) Nobel Biocare replace tapered (2) Uniti (3) Lifecare self-threaded tapered ceme...

متن کامل

The Frequency of Dentists’ Use and Satisfaction of Different Dental Implant Systems in Qom City, (Iran)

Abstract Background and Objectives: Considering the increasing use of implant, many dentists are willing to use implants with the highest quality and ease of work. Therefore, the present study was performed to investigate the frequency of use and satisfaction of the dentists from different dental implant systems in Qom city.   Methods: In this descriptive and cross-sectional study, a questionn...

متن کامل

Comparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts

Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...

متن کامل

Clinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading

Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 1999