BACKGROUND A left ventricular assist device (LVAD) is normally contraindicated in significant aortic regurgitation (AR) and requires intraoperative valve repair or exclusion. Nevertheless, AR can coexist with an LVAD, so a valid question when asked might still be of clinical significance. The purpose of this study is to analyze the effects of valve regurgitation on the pumping efficacy of continuous and pulsatile LVADs with a computational method. METHODS A cardiovascular model was developed based on the Windkessel model, which reflects the hemodynamic flow resistance and the blood wall elasticity. Using the Windkessel model, important cardiovascular components, such as the right atrium, right ventricle, pulmonary artery, pulmonary vein, left atrium (LA), left ventricle (LV), aorta, and branching blood vessels, were expressed. RESULTS In the case of AR, continuous and pulsatile LVADs improved cardiac output and reduced mechanical load slightly. In the case of mitral regurgitation, the LVADs improved cardiac output (cardiac outputs were about 5 L/min regardless of the severity of regurgitation) and reduced afterload significantly. CONCLUSION AR reduced both continuous and pulsatile LVAD function significantly while mitral regurgitation did not affect their pumping efficacy.
منابع مشابه
Design an Equivalent Left Ventricular Assist Device for Medical Equipment Labs
LVAD is a mechanical pump supporting a weak heart function and blood flow. Sometimes, the heart may not recover fast enough to take over the pumping action immediately after surgery, in such patients a temporary support device has been employed to maintain the pumping action until the patient’s own heart recovers. This device can be considered as a temporary alternative before the process of ar...
متن کاملComputational Analysis of Pumping Efficacy of a Left Ventricular Assist Device according to Cannulation Site in Heart Failure with Valvular Regurgitation
Mitral valve regurgitation (MR) causes blood to flow in two directions during contraction of the left ventricle (LV), that is, forward into the aorta and backward into the left atrium (LA). In aortic valve regurgitation (AR), leakage occurs from the aorta into the LV during diastole. Our objective is to analyze the contribution of a left ventricular assist device (LVAD) to MR and AR for the fol...
متن کاملTricuspid regurgitation in left ventricular assist device patients.
DMBlackstone EH. Tricuspid valve repair: durability and risk factors for failure. J Thorac Cardiovasc Surg 2004;127:674–85. [13] Chumnanvej S, Wood MJ, MacGillivray TE, Vidal Melo MF. Effect of tricuspid annuloplasty on postoperative tricuspid regurgitation following left ventricular assist device implantation. Anesth Analg 2006; 102:SCA54. [14] Scalia GM, McCarthy PM, Savage RM, Smedira NG, Th...
متن کاملApplication of centrifugal pump in right ventricular failure due to pulmonary artery hypertension. (A case report)
Background: It has not been yet developed a ost suitable method to treat right ventricular failure due to pulmonar artery hypertention resulted from ventricular arrhythia. Though some case reports about patients ready to heart transplant using left assist device or biventral assist device as bridge have been published in Journals, but nocase concerning application of centrifugal pump for treatm...
متن کاملLeft ventricular assist devices decrease fixed pulmonary hypertension in cardiac transplant candidates.
OBJECTIVE Fixed pulmonary hypertension is a contraindication for cardiac transplantation because of the increased risk of donor heart failure. We sought to determine whether left ventricular assist devices improve fixed pulmonary hypertension in cardiac transplant candidates to enable safe cardiac transplantation. METHODS Thirty-five consecutive cardiac transplant candidates (age 56 +/- 6 yea...