Regional diastolic function in ischaemic heart disease using pulsed wave Doppler tissue imaging.

نویسندگان

  • M A García-Fernández
  • J Azevedo
  • M Moreno
  • J Bermejo
  • N Pérez-Castellano
  • P Puerta
  • M Desco
  • C Antoranz
  • J A Serrano
  • E García
  • J L Delcán
چکیده

AIMS The aim of this study was to determine the utility of pulsed wave Doppler tissue imaging in the evaluation of regional left ventricular diastolic function in patients with ischaemic heart disease. METHODS AND RESULTS In 30 normal subjects and 43 patients with ischaemic heart disease, Doppler tissue imaging was performed in each of the 16 segments of the myocardium. The following diastolic pulsed wave Doppler tissue imaging parameters were obtained for each segment: (1) regional early diastolic peak velocity (regional e wave cm.s-1); (2) regional late diastolic peak velocity (regional a wave cm.s-1); (3) regional diastolic e/a velocity ratio; and (4) the regional isovolumic relaxation time, defined as the time interval from the second heart sound to the onset of the diastolic E wave. In patients with ischaemic heart disease, each of these parameters was evaluated and compared in ischaemic and normally perfused segments, based on the presence or absence of obstructive lesions of the supplying coronary artery. In patients with coronary artery disease, several differences were observed between diseased and normal wall segments: the mean segmental peak early diastolic velocity (e wave) was reduced (mean +/- SD: 6.4 +/- 2.1 cm.s-1 vs 8.5 +/- 2.8 cm.s-1; P < 0.01); the e/a diastolic velocity ratio was decreased (0.95 +/- 0.3 vs 1.5 +/- 0.6, respectively; P < 0.01) and the regional isovolumic relaxation time was prolonged (104 +/- 36.7 ms vs 69.6 +/- 30 ms; P < 0.01. No differences were observed in any of these parameters between the normally perfused segments of ischaemic patients and normal subjects. Patients with a normal transmitral diastolic Doppler inflow pattern had a mean of 3.7 +/- 2.7 myocardial segments with a local e/a pulsed wave Doppler tissue imaging velocity ratio < 1, fewer than those with an inverted diastolic transmitral Doppler inflow pattern (10.3 +/- 3 segments; P < 0.001). Overall sensitivity and specificity for an inverted local e/a ratio and a local isovolumetric relaxation time > or = 85 ms were of 62% and 72% and 69% and 80%, respectively. CONCLUSION Regional diastolic wall motion is impaired at baseline in ischaemic myocardial segments, even when systolic contraction is preserved. Pulsed wave Doppler tissue imaging is a useful non-invasive technique which allows the assessment of regional diastolic performance and dynamics of the left ventricular myocardium. Further studies are required to define this role in the evaluation of coronary heart disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The influence of Asthma on Right Ventricular Systolic and Diastolic Function in Children according to Tissue Doppler Echocardiography

Introduction:Asthma is the most common chronic inflammatory condition affecting the lower airways among children. Asthma may influence right ventricular (RV) function and patients may develop right ventricular hypertrophy, pulmonary hypertension and cor pulmonale. The main objective of this study is to determine RV dysfunction in asymptomatic asthmatic children as detected by ti...

متن کامل

The Effect of Bronchial Asthma on Interatrial Electromechanical Delay Coupling Obtained Using Tissue Doppler Imaging

Background: Asthma is a predisposing factor for the development of atrial fibrillation. Asthma disturbs the electrophysiology in the right and left atrium. The aim of this study was to evaluate atrial electromechanical delay by coupling obtained from tissue Doppler imaging (TDI) in children. Methods: A cross-sectional study was conducted on 50 patients with Bronchial Asthma, compared with 50 hea...

متن کامل

بررسی اثر کاهش حجم بر روی پارامترهای دیاستولیک اکو کاردیوگرافی در بیماران همودیالیزی

Background: Cardiovascular problems including arterial hypertension, coronary artery diseases, congestive heart failure are prevalent among chronic hemodialyzed patients. Ultrafiltration of hemodialyzed patient's serum, which culminating in intravascular volume reduction, is frequently used during hemodialysis. One of the restrictions of the echocardiographic evaluation of the diastolic heart f...

متن کامل

Echocardiographic Evaluation of left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation

Extended abstract Echocardiographic Evaluation of Left Ventricular Function and Geometry in Pediatric Patients with Kidney Transplantation Cardiovascular disease (CVD) is an important, leading cause of mortality and morbidity in patients with chronic kidney disease (CKD) as well as in renal transplant recipients. Cardiovascular complications become more important in children because of the i...

متن کامل

Cardiac allograft function during the first year after transplantation in rejection-free children and young adults.

BACKGROUND Allograft dysfunction is a common finding early after heart transplant (HT). We sought to assess the recovery of left (LV) and right ventricular (RV) function during the first year after HT in children and young adults using pulsed-wave tissue Doppler imaging. METHODS AND RESULTS We analyzed serially performed echocardiography in 44 pediatric HT recipients (median age: 7.3 years at...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 20 7  شماره 

صفحات  -

تاریخ انتشار 1999