Noticeable, troublesome and objectionable limits of blur
نویسندگان
چکیده
We investigated limits at which induced blur becomes noticeable, troublesome and objectionable. We used 15 cyclopleged subjects, a Badal optometer with lines of three high contrast letters as targets, 3-6 mm artificial pupils, and 0.0-0.7 logMAR letter sizes. For 0.0 logMAR size, mean "noticeable" blur limits were +/-0.33D, +/-0.30D and +/-0.28D at 3 mm, 4 mm and 6 mm, respectively, but increased by about 70% for 0.7 logMAR letters. All limits reduced by about 17% as pupil size increased from 3 mm to 6 mm. Letter size had a significant influence on all blur limits (1.6-2.1 times), but blur direction had no significant effect. Magnitudes of "troublesome" and 'objectionable" limits were 1.6-1.8 times and 2.1-2.5 times relative to "noticeable" limits, respectively. Our results suggest criteria for troublesome and objectionable blur are relatively unaffected by letter size.
منابع مشابه
Blur limits for defocus, astigmatism and trefoil
We investigated the limits at which blur due to defocus, crossed-cylinder astigmatism, and trefoil became noticeable, troublesome or objectionable. Black letter targets (0.1, 0.35 and 0.6 logMAR) were presented on white backgrounds. Subjects were cyclopleged and had effectively 5mm pupils. Blur was induced with a deformable, adaptive-optics mirror operating under open-loop conditions. Mean defo...
متن کاملA relationship between tolerance of blur and personality.
PURPOSE To determine whether tolerance of dioptric spherical defocus is related to measures of personality. Clinical observations suggest that there is individual variability in tolerance of blur. METHODS A computer-controlled Badal optometer was used to measure just-noticeable blur and just-objectionable blur responses to positive lens defocus. Blur tolerance was defined as the difference be...
متن کاملJust noticeable and objectionable group delays in digital hearing aids.
Group delay in a digital signal processing (DSP) hearing aid may be perceived as an echo in the sound heard by a wearer listening to his or her own voice, due to a combination of unprocessed sound received at the ear through head and air pathways and delayed sound reaching the eardrum through the hearing aid. Depending on the amount, this delay may be audible or objectionable and can even resul...
متن کاملRemoving Camera Shake from a Single Photograph
Camera shake during exposure leads to objectionable image blur and ruins many photographs. Conventional blind deconvolution methods typically assume frequency-domain constraints on images, or overly simplified parametric forms for the motion path during camera shake. Real camera motions can follow convoluted paths, and a spatial domain prior can better maintain visually salient image characteri...
متن کاملWhat is an "Objectionable Organism"?
So, 21 CFR 211.113 limits the discussion to “products not required to be sterile” and 21 CFR211.84 states that the concern is “microbiological contamination that is objectionable in view of its intended use” leaving 21 CFR 211.165 to require lab testing relevant to “drug product required to be free of objectionable microorganisms”. This clearly defined concept of an “objectionable” organism the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 45 شماره
صفحات -
تاریخ انتشار 2005