Contrast enhancement of intracranial lesions: conventional T1-weighted spin-echo versus fast spin-echo MR imaging techniques.

نویسندگان

  • T Sugahara
  • Y Korogi
  • Y Ge
  • Y Shigematsu
  • L Liang
  • K Yoshizumi
  • M Kitajima
  • M Takahashi
چکیده

BACKGROUND AND PURPOSE The T1-weighted fast spin-echo (T1-FSE) MR imaging sequence is not used routinely, since the speed advantage is not as dramatic as it is in T2-weighted imaging. We evaluated the T1-FSE sequence to determine whether this technique can replace the conventional T1-weighted spin-echo (T1-SE) sequence for routine contrast-enhanced imaging. METHODS Sixty-nine patients with intracranial enhancing lesions underwent both T1-SE and T1-FSE sequences in a random order after administration of contrast agent. Acquisition time was 55 seconds for the T1-FSE sequence and 2 minutes 38 seconds for the SE sequence. The conspicuity of enhancing lesions, peritumoral edema, and gray-to-white matter contrast as well as motion and flow artifacts were analyzed. Signal-to-noise ratios of enhancing lesions, gray matter, and white matter as well as contrast-to-noise ratios (CNRs) of enhancing lesions, with gray matter with white matter as the standard, were calculated. RESULTS The conspicuity of enhancing lesions was better on T1-FSE sequences than on T1-SE sequences, although the difference in the CNRs of enhancing lesions did not reach significance. Images obtained with the T1-FSE sequence showed less flow and motion artifacts than did those obtained with the T1-SE sequence. The conspicuity of peritumoral edema and gray-to-white matter contrast was lower on the T1-FSE images than on the T1-SE images. CONCLUSION The T1-FSE sequence reduces imaging time and has the potential to replace the conventional T1-SE sequence for the evaluation of enhancing lesions in the brain when time is a consideration.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T1-weighted three-dimensional magnetization transfer MR of the brain: improved lesion contrast enhancement.

PURPOSE We developed and evaluated clinically T1-weighted three-dimensional gradient-echo magnetization transfer (MT) sequences for contrast-enhanced MR imaging of the brain. METHODS A short-repetition-time, radio frequency-spoiled, 3-D sequence was developed with a 10-millisecond MT pulse at high MT power and narrow MT pulse-frequency offset, and the enhancing lesion-to-normal white matter b...

متن کامل

Gadolinium-DTPA-enhanced MR imaging of spinal neoplasms: preliminary investigation and comparison with unenhanced spin-echo and STIR sequences.

Unenhanced T1- and T2-weighted spin-echo, short inversion time inversion recovery (STIR), and gadolinium-DTPA (Gd-DTPA)-enhanced spin-echo and STIR imaging techniques were used in 20 patients as part of a multicenter study to assess the safety and efficacy of Gd-DTPA in spinal imaging. Five patients had normal MR scans. Of those with lesions, both Gd-DTPA-enhanced T1-weighted spin-echo and unen...

متن کامل

Inversion-recovery echo-planar MR in adult brain neoplasia.

PURPOSE A T1-weighted multishot inversion-recovery (IR) echo-planar MR imaging (EPI) sequence was developed to improve intracranial tissue differentiation; its diagnostic utility was compared with that of conventional axial T1-weighted spin-echo and axial T2-weighted turbo spin-echo sequences. METHODS Eighteen patients with known or suspected primary or metastatic brain neoplasia were imaged ...

متن کامل

MR enhancement of brain lesions: increased contrast dose compared with magnetization transfer.

PURPOSE To compare image contrast and lesion conspicuity of enhancing intracranial lesions obtained with T1-weighted and magnetization transfer T1-weighted spin-echo sequences after administration of standard (0.1 mmol/kg body weight) and triple doses of gadobutrol. METHODS Twenty-four patients with a total of 34 enhancing intracranial lesions were studied with T1-weighted and magnetization t...

متن کامل

Comparison of spin-echo MR pulse sequences for imaging of the brain.

PURPOSE To determine the value of the gradient- and spin-echo (GRASE) technique as compared with the fast spin-echo and conventional spin-echo techniques in MR imaging of the brain. METHODS Sixty-six patients with ischemic and neoplastic brain lesions were examined with T2-weighted spin-echo, fast spin-echo, and GRASE sequences. Three independent observers evaluated the contrast characteristi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 20 8  شماره 

صفحات  -

تاریخ انتشار 1999