MR guided HIFU in Cadaver Breasts for Pre-Operative Tumor Localization of Non-Palpable Breast Tumors as an Alternative to Needle Wire Tumor Localization

نویسندگان

  • R. R. Bitton
  • E. Kaye
  • B. Daniel
  • K. Butts Pauly
چکیده

Introduction Breast conservation surgery is an accepted alternative to mastectomy in patients suffering from limited stage breast cancer. Physicians are increasingly confronted with non-palpable breast lesions that are only visible on MRI. Since these tumors are non-palpable, current methods to locate them include pre-operative ultrasound, X-ray mammography, and MRI image-guided wire placement. However, image-guided wire localization lacks precision; positive tumor margins are discovered in 14-57% of patients [1]. A recent study demonstrated the potential of MR guided High Intensity Focused Ultrasound (MRgHIFU) for pre-operative localization of nonpalpable breast lesions, as compared to the current wire placement method [2]. MRgHIFU was used to create lesions fully registered with the MRI, circumscribing the tumor, and thus, providing a visible and palpable lesion that the surgeon could use as a guide for excision during breast conservation surgery. While this initial study was performed in chicken breast tissue, a critical issue for the technique has been the performance of the technique in actual breast tissue, with a high percentage of fat. Therefore, the purpose of this study was to examine the visibility and palpability of focused ultrasound lesions in fatty human breast tissue. Materials and Methods The HIFU localization was performed in a GE 3T scanner using the InSightec ExAblate 2000 system and a 4” circular surface coil designed for MRgHIFU in the breast. In this study 18 sonications (120W acoustic power, 20s) spaced 5mm apart, were made around the perimeter of an arbitrary prescribed “tumor” square, representing a non-palpable tumor area. The ablated area circumscribed a 24 mm x 24 mm square section of the breast, crossing between fibroglandular tissue, as well as fat. Sonications were prescribed in the x-z plane and visualized on TIw FSE (TR=200-400ms, TE=12ms) magnitude images during heating [3]. MR guided Acoustic Radiation Force Imaging (MR-ARFI) data was collected during the same HIFU session. Using MR-ARFI data, displacement maps were obtained to show the difference between the pre and post sonication spots, potentially relating to a change in tissue stiffness. The temperature of the breast was monitored using fiber optic temperature sensors to insure pre and post ablation displacement measurements were evaluated at similar overall tissue temperatures (Luxtron, Inc.). Results T1w FSE images confirmed changes in T1 due to local heating of each sonication spot (Fig 1a). These images also showed a slight structural change during the heating phase of some sonications. The tissue shrank towards the nearest heated fibroglandular tissue in sonications closest to the edge of the breast (along bottom right of square). Stiffening of the tissue, where sonications corresponded with fibroglandular tissue, could be felt upon palpation of the breast at room temperature. Visible changes in the tissue also demarcated the sonication square by creating tissue voids in purely fat sonications, and a darkening of the ablated square perimeter (Fig 1b). Maximum Intensity Projections (MIP) of MR-ARFI maps of the tissue taken pre and post ablation show a reduction in the amount of displacement for most post ablation spots (Fig 2). The reduced displacements are a likely indicator of a stiffer tissue, which is more difficult to displace using the same acoustic power. A greater displacement post ablation in some sonications (along bottom right of square) could be due to the shrinking of the tissue during neighboring ablations. In that case, the displacement measurements would correspond to areas that had not actually been ablated. Conclusion This study showed that MRgHIFU treatments in ex vivo human cadaver breasts were able to create visual and palpable lesions. ARFI was used to verify tissue displacement changes in sonicated areas, indicating a stiffening of the ablated spot. By creating both visual and palpable lesions that are fully registered with diagnostic MR images surgeons can potentially use this technique for pre-operative localization in breast conservation surgeries. References [1] RJ Gray et al. “Randomized prospective evaluation of a novel technique for biopsy or lumpectomy of nonpalpable breast lesions.” Ann Surg Oncol 2001;8. [2]A.C. Schmitz, et al, “3.0-T MR-guided focused ultrasound for preoperative localization of nonpalpable breast lesions....” JMRI,. 2009; Oct;30(4):884-9. [3] K. Hynynen, N MaDannold, RV Mulkern, FA Jolesz “Temperature monitoring in fat with MRI.” MRM , 2000; 43. Acknowledgements NIH grants P41 RR 009784, NIH/NCI CA-09695-19. a) b) Figure 1. a) MIP of the T1w FSE heating images obtained during ablation subtracted from the non heated reference image. B) Photograph of ex-vivo human breast after MRgHIFU ablation of 24mm square perimeter. Arrows point to square demarcated by voids and tissue darkening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Ultrasound / Radio-guided Occult Lesion Localization in Non-palpable Breast Lesions

Objective(s): Controversy exists about the localization of non-palpable breast lesions. In many countries, the gold standard for the diagnosis of these lesions is needle localization due to its accuracy. This study sought to compare the ultrasoundand radio-guided occult lesion localization (ROLL) as a simple method with the conventional procedures in terms of their diagnostic power. Methods: Th...

متن کامل

Injectable iodine-125 labeled tissue marker for radioactive localization of non-palpable breast lesions.

We have developed a 125I-radiolabeled injectable fiducial tissue marker with the potential to replace current methods used for surgical guidance of non-palpable breast tumors. Methods in routine clinical use today such as radioactive seed localization, radio-guided occult lesion localization and wire-guided localization suffers from limitations that this injectable fiducial tissue marker offers...

متن کامل

Needle localization of non-palpable breast lesions.

Screening mammography identifies suspicious, non palpable mammary lesions. Mammographic needle localization (MNL) is currently being used to facilitate excision biopsy of these lesions. Thirty-two patients underwent biopsies of the breast after MNL for non-palpable lesions. Mammographic indications for biopsy consisted of microcalcifications (48%), mass or abnormal density (21%) or mass+abnorma...

متن کامل

Comparison of outcomes of surgeon-performed intraoperative ultrasonography-guided wire localization and preoperative wire localization in nonpalpable breast cancer patients undergoing breast-conserving surgery

This study aimed to determine the efficacy of intraoperative ultrasonography-guided wire localization guided breast-conserving surgery (BCS) for nonpalpable breast cancer and compare it to conventional preoperative wire localization (PWL) guided surgery.We retrospectively analyzed the medical charts of 214 consecutive nonpalpable breast cancer patients who underwent BCS using intraoperative ult...

متن کامل

Diagnostic Value of Hook Wire Localization Technique for Non-Palpable Breast Lesions

BACKGROUND The aim of this study was to investigate the validity of hook wire localization biopsy for non-palpable breast lesions which were detected by ultrasonography (USG) or mammography (MMG). METHODS In this retrospective study, USG or MMG-guided hook wire localization technique was performed on 83 patients who had non-palpable breast lesions. Then histopathological examination was perfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009