A new method for determining gastric acid output using a wireless pH-sensing capsule.
نویسندگان
چکیده
BACKGROUND Gastro-oesophageal reflux disease (GERD) and gastric acid hypersecretion respond well to suppression of gastric acid secretion. However, clinical management and research in diseases of acid secretion have been hindered by the lack of a non-invasive, accurate and reproducible tool to measure gastric acid output (GAO). Thus, symptoms or, in refractory cases, invasive testing may guide acid suppression therapy. AIM To present and validate a novel, non-invasive method of GAO analysis in healthy subjects using a wireless pH sensor, SmartPill (SP) (SmartPill Corporation, Buffalo, NY, USA). METHODS Twenty healthy subjects underwent conventional GAO studies with a nasogastric tube. Variables impacting liquid meal-stimulated GAO analysis were assessed by modelling and in vitro verification. Buffering capacity of Ensure Plus was empirically determined. SP GAO was calculated using the rate of acidification of the Ensure Plus meal. Gastric emptying scintigraphy and GAO studies with radiolabelled Ensure Plus and SP assessed emptying time, acidification rate and mixing. Twelve subjects had a second SP GAO study to assess reproducibility. RESULTS Meal-stimulated SP GAO analysis was dependent on acid secretion rate and meal-buffering capacity, but not on gastric emptying time. On repeated studies, SP GAO strongly correlated with conventional basal acid output (BAO) (r = 0.51, P = 0.02), maximal acid output (MAO) (r = 0.72, P = 0.0004) and peak acid output (PAO) (r = 0.60, P = 0.006). The SP sampled the stomach well during meal acidification. CONCLUSIONS SP GAO analysis is a non-invasive, accurate and reproducible method for the quantitative measurement of GAO in healthy subjects. SP GAO analysis could facilitate research and clinical management of GERD and other disorders of gastric acid secretion.
منابع مشابه
Gastric pH and motility in a porcine model of acute lung injury using a wireless motility capsule
BACKGROUND Evaluation of gastric pH and motility in a porcine model of acute lung injury using a novel, wireless motility capsule. MATERIAL/METHODS A motility capsule was applied into the stomach of 7 Pietrain pigs with acute lung injury induced by high volume saline lavage. Wireless transmission of pH, pressure and temperature data was performed by a recorder attached to the animal's abdomen...
متن کاملDiagnosis and Treatment of Small Bowel Cancers Using Radioactive Gold Nanoparticles and Wireless Fluorescence Capsule Endoscopy
Background: Therapeutic and diagnosis properties of radioactive gold nanoparticle (198-AuNPs) cause them to be suitable for detection and treatment of tumors.Objective: Electrical and optical properties of PEG-198AuNPs were examined in this paper. Polyethylene Glycol (PEG)-198 AuNPs can be used for treatment and diagnosis of small intestine tumors.Methods: Wireless fluorescence capsule endoscop...
متن کاملThe assessment of regional gut transit times in healthy controls and patients with gastroparesis using wireless motility technology.
BACKGROUND Wireless pH and pressure motility capsule (wireless motility capsule) technology provides a method to assess regional gastrointestinal transit times. AIMS To analyse data from a multi-centre study of gastroparetic patients and healthy controls and to compare regional transit times measured by wireless motility capsule in healthy controls and gastroparetics (GP). METHODS A total o...
متن کاملLarge Buffering Effect of the Duodenal Bulb in Duodenal Switch: a Wireless pH-Metric Study
INTRODUCTION Bariatric procedures result in massive weight loss, however, not without side effects. Gastric acid is known to cause marginal ulcers, situated in the small bowel just distal to the upper anastomosis. We have used the wireless BRAVO™ system to study the buffering effect of the duodenal bulb in duodenal switch (DS), a procedure in which the gastric sleeve produces a substantial amou...
متن کاملSTCS-GAF: Spatio-Temporal Compressive Sensing in Wireless Sensor Networks- A GAF-Based Approach
Routing and data aggregation are two important techniques for reducing communication cost of wireless sensor networks (WSNs). To minimize communication cost, routing methods can be merged with data aggregation techniques. Compressive sensing (CS) is one of the effective techniques for aggregating network data, which can reduce the cost of communication by reducing the amount of routed data to t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Alimentary pharmacology & therapeutics
دوره 37 12 شماره
صفحات -
تاریخ انتشار 2013