Utility and feasibility of integrating pulse oximetry into the routine assessment of young infants at primary care clinics in Karachi, Pakistan: a cross-sectional study
نویسندگان
چکیده
BACKGROUND Hypoxemia may occur in young infants with severe acute illnesses or congenital cardiac anomalies, but is not reliably detected on physical exam. Pulse oximetry (PO) can be used to detect hypoxemia, but its application in low-income countries has been limited, and its feasibility in the routine assessment of young infants (aged 0-59 days) has not been previously studied. The aim of this study was to characterize the operational feasibility and parent/guardian acceptability of incorporating PO into the routine clinical assessment of young infants in a primary care setting in a low-income country. METHODS This was a cross-sectional study of 862 visits by 529 infants at two primary care clinics in Karachi, Pakistan (March to June, 2013). After clinical assessment, oxygen saturation (Sp02) was measured by a handheld PO device (Rad-5v, Masimo Corporation) according to a standardized protocol. Performance time (PT) was the time between sensor placement and attainment of an acceptable PO reading (i.e., stable SpO2 + 1% for at least 10 s, heart rate displayed, and adequate signal indicators). PT included the time for one repeat attempt at a different anatomical site if the first attempt did not yield an acceptable reading within 1 min. Parent/guardian acceptability of PO was based on a questionnaire and unprompted comments about the procedure. All infants underwent physician assessment. RESULTS Acceptable PO readings were obtained in ≤ 1 and ≤ 5 min at 94.4% and 99.8% of visits, respectively (n = 862). Median PT was 42 s (interquartile range 37; 50). Parents/guardians overwhelmingly accepted PO (99.6% overall satisfaction, n = 528 first visits). Of 10 infants with at least one visit with Sp02 <92% on a first PO attempt, 3 did not have a significant acute illness on physician assessment. There were no PO-related adverse events. DISCUSSION Using a commercially available handheld pulse oximeter, acceptable Sp02 measurements were obtained in nearly all infants in under 1 minute. The procedure was readily integrated into existing assessment pathways and parents/guardians had positive views of the technology. CONCLUSIONS When incorporated into routine clinical assessment of young infants at primary care clinics in a low-income country, PO was feasible and acceptable to parents/guardians. Future research is needed to determine if the introduction of routine PO screening of young infants will improve outcomes in low-resource settings.
منابع مشابه
A Pilot Study of a 6-Week Parenting Program for Mothers of Pre-school Children Attending Family Health Centers in Karachi, Pakistan
Background Recently, parenting programs to address behavioural and emotional problems associated with child maltreatment in developing countries have received much attention. There is a paucity of literature on effective parent education interventions in the local context of Pakistan. This study aimed to assess the feasibility of offering a 6-week parenting program for mothers of pre-school chi...
متن کاملEvaluation of Pulse Oximetry in the Early Detection of Congenital Heart Diseases in Newborns
Background: Congenital heart diseases, which are asymptomatic at birth, are the most important causes of infant mortality. This study aimed to evaluate the role of pulse oximetry in the early detection of congenital heart diseases among newborns.Methods: In this cross-sectional descriptive study, 1230 newborns who were born in university hospitals in an urban area of Iran were placed unde...
متن کاملMale partners' knowledge and practices of antenatal care in district Swat, Khyber Pakhtunkhwa, Pakistan: A cross-sectional study
Background & aim: Active participation of men in antenatal care and their considerable knowledge about this issue is resulted in favorable pregnancy outcomes. This study aimed to assess the knowledge and practices of male partners regarding antenatal care (ANC) and their associated factors in district Swat, Khyber Pakhtunkhwa, Pakistan (KPK). Methods<...
متن کاملEvaluation of Pulse Oximetry in the Early Diagnosis of Cardiac and NonCardiac Diseases in Healthy Newborns
Background: Critical congenital heart diseases (CCHDs) are among the most common birth malformations. This study aimed to determine the cardiac and noncardiac diseases in the Iranian healthy newborns using pulse oximetry (POX) as a suggested screening method.Methods: In this cross-sectional study, healthy term and near term neonates who were born from October 2017 to March 2018 were evalu...
متن کاملIntegrating the Population Perspective into Health System Performance Assessment (IPHA): Study Protocol for a Cross-Sectional Study in Germany Linking Survey and Claims Data of Statutorily and Privately Insured
Background Health system performance assessment (HSPA) is a major tool for evidence-based governance in health systems and patient/population-orientation is increasingly considered as an important aspect. The IPHA study aims (1) to undertake a comprehensive performance assessment of the German health system from a population perspec...
متن کامل