Improved image quality of intracranial aneurysms: 3.0-T versus 1.5-T time-of-flight MR angiography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE We hypothesize that the nearly doubling of signal-to-noise ratio at 3.0 T compared with that at 1.5 T yields improved clinical MR angiograms and enables superior visualization of intracranial aneurysms. The goal of this study was to determine whether 3.0-T time-of-flight (TOF) MR angiography is superior to 1.5-T TOF MR angiography in the detection and characterization of intracranial aneurysms. METHODS Fifty consecutive patients referred for MR angiography of a known or suspected intracranial aneurysm underwent 3-T TOF MR angiography. Seventeen of these 50 patients had also previously undergone 1.5-T TOF MR angiography and these images were used as a basis for comparison with images obtained at 3.0 T. Fourteen of 23 patients in whom aneurysms were identified also underwent prior conventional angiography, which was used as the reference standard. Readers blinded to patient history identified the presence and location of aneurysm(s) on angiograms and graded images for overall image quality by using a five-point scale. RESULTS Twenty-eight aneurysms were identified in 23 of 50 patients. Seventeen aneurysms in 17 patients had been documented with 1.5-T MR angiography. The 3.0-T technique had a higher mean image quality score than that of the 1.5-T MR technique (P <.0001). Both 3.0-T and 1.5-T TOF MR angiography depicted all the aneurysms that had been documented by conventional angiography. CONCLUSION 3D TOF MR angiography at 3 T offers superior depiction of intracranial aneurysms compared with that of 1.5-T TOF MR angiography.
منابع مشابه
Evaluation of cerebral aneurysms with high-resolution MR angiography using a section-interpolation technique: correlation with digital subtraction angiography.
BACKGROUND AND PURPOSE The objective was to evaluate the results of high-resolution, fast-speed, section-interpolation MR angiography and digital subtraction angiography (DSA), thereby examining the potential use of a primary noninvasive screening test for intracranial aneurysms. METHODS The images were obtained in 39 cerebral aneurysmal lesions from 30 patients with a time-of-flight MR angio...
متن کاملLarge-cohort comparison between three-dimensional time-of-flight magnetic resonance and rotational digital subtraction angiographies in intracranial aneurysm detection.
BACKGROUND AND PURPOSE The value of MR angiography varies in diagnosis of intracranial aneurysms due to the difference of equipment and imaging technique. This study was to compare the effectiveness of 3-dimensional time-of-flight MR angiography at 3 T and rotational digital subtraction angiography, both with volume rendering (VR), in detecting intracranial aneurysms. METHODS One hundred thir...
متن کاملDiagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T.
PURPOSE Our goal was to determine the accuracy of MR angiography at 0.5 T for the diagnosis of intracranial aneurysms. METHODS We retrospectively studied 140 patients, 70 with acute subarachnoid hemorrhage, who were either at high or low risk for intracranial aneurysm. Three-dimensional time-of-flight MR angiography was typically performed to cover the circle of Willis, with a volume thicknes...
متن کاملBlinded prospective evaluation of sensitivity of MR angiography to known intracranial aneurysms: importance of aneurysm size.
PURPOSE To determine the sensitivity of time-of-flight and phase-contrast MR angiography for the detection of intracranial aneurysms. METHODS Sixteen patients with 27 intracranial aneurysms previously identified with conventional angiography and 19 control patients were examined with three-dimensional time-of-flight, three-dimensional phase-contrast MR angiography, and standard MR imaging. Su...
متن کاملIntracranial aneurysms treated with Guglielmi detachable coils: is contrast material necessary in the follow-up with 3D time-of-flight MR angiography?
BACKGROUND AND PURPOSE Three-dimensional time-of-flight (TOF) MR angiography has been evaluated in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDCs) with good results. Some of the studies used contrast material in addition to the 3D TOF MR technique and others did not. We assessed the usefulness of contrast material with 3D TOF MR angiography by comparing th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 25 1 شماره
صفحات -
تاریخ انتشار 2004